Long-term outcome after ICD and CRT implantation and influence of remote device follow-up: the ALTITUDE survival study.

نویسندگان

  • Leslie A Saxon
  • David L Hayes
  • F Roosevelt Gilliam
  • Paul A Heidenreich
  • John Day
  • Milan Seth
  • Timothy E Meyer
  • Paul W Jones
  • John P Boehmer
چکیده

BACKGROUND Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy-defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a network. METHODS AND RESULTS Survival status in patients implanted with ICD and CRT devices across the United States from a single manufacturer was assessed. Outcomes were compared between patients followed in device clinic settings and those who regularly transmit remote data collected from the device an average of 4 times monthly. Shock delivery and electrogram analysis could be ascertained from patients followed on the network, enabling survival after ICD shock to be evaluated. One- and 5-year survival rates in 185,778 patients after ICD implantation were 92% and 68% and were 88% and 54% for CRT-D device recipients. In 8228 patients implanted with CRT-only devices, survival was 82% and 48% at 1 and 5 years, respectively. For the 69,556 ICD and CRT-D patients receiving remote follow-up on the network, 1- and 5-year survival rates were higher compared with those in the 116,222 patients who received device follow-up in device clinics only (50% reduction; P<0.0001). There were no differences between patients followed on or off the remote network for the characteristics of age, gender, implanted device year or type, and economic or educational status. Shock therapy was associated with subsequent mortality risk for both ICD and CRT-D recipients. CONCLUSIONS Survival after ICD and CRT-D implantation in patients treated in naturalistic practice compares favorably with survival rates observed in clinical trials. Remote follow-up of device data is associated with excellent survival, but arrhythmias that result in device therapy in this population are associated with a higher mortality risk compared with patients who do not require shock therapy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Arrhythmia/Electrophysiology Long-Term Outcome After ICD and CRT Implantation and Influence of Remote Device Follow-Up The ALTITUDE Survival Study

Background—Outcome data for patients receiving implantable cardioverter-defibrillator (ICD) and cardiac resynchronization therapy– defibrillator (CRT-D) devices treated outside of clinical trials are lacking. No clinical trial has evaluated mortality after device implantation or after shock therapy in large numbers of patients with implanted devices that regularly transmit device data over a ne...

متن کامل

Influence of remote monitoring on long-term cardiovascular outcomes after cardioverter-defibrillator implantation.

AIMS Device-based remote monitoring (RM) has been linked to improved clinical outcomes at short to medium-term follow-up. Whether this benefit extends to long-term follow-up is unknown. We sought to assess the effect of device-based RM on long-term clinical outcomes in recipients of implantable cardioverter-defibrillators (ICD). METHODS We performed a retrospective cohort study of consecutive...

متن کامل

Percutaneous repair of sinus venosus defect with anomalous pulmonary venous return.

pace 2013;15(Suppl 1):i14–i16. 8. Varma N, Epstein A, Irimpen A, Schweikert R, Shah J, Love CJ. Efficacy and safety of automatic remote monitoring for ICD follow-up: the TRUST trial. Circulation 2010; 122:325–332. 9. Varma N. Rationale and design of a prospective study of the efficacy of a remote monitoring system used in ICD follow-up: the Lumos-T reduces routine office device follow-up study ...

متن کامل

Long-term Outcome of Limbal Stem Cell Transplantation for the Management of Total Limbal Stem Cell Deficiency due to a Chemical Burn

Purpose: To evaluate the long-term outcome of limbal stem cell transplantation (LSCT) for the management of total limbal stem cell deficiency (LSCD) due to chemical burn in Labbafinejad Medical Center (LMC). Methods: Records of patients with a history of severe (i.e. grade III and IV) chemical burns, who were referred to LMC and underwent LSCT, were reviewed and data including demographic chara...

متن کامل

Complications in recipients of cardioverter-defibrillator or cardiac resynchronization therapy: Insights from Silesian Center Defibrillator registry.

BACKGROUND Current real-life information from all-comers registries from middle and east Europe about the incidence and type of complications during long-term follow-up of patients with cardioverters-defibrillators (ICD) and cardiac resynchronization devices-defibrillators (CRT-D) is still insufficient. The aim of the study was to assess the incidence and determinants of short- and long-term co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 122 23  شماره 

صفحات  -

تاریخ انتشار 2010