Detection of pulmonary embolism with combined ventilation-perfusion SPECT and low-dose CT: head-to-head comparison with multidetector CT angiography.
نویسندگان
چکیده
UNLABELLED The diagnosis of pulmonary embolism (PE) is usually established by a combination of clinical assessment, D-dimer testing, and imaging with either pulmonary ventilation-perfusion (V/Q) scintigraphy or pulmonary multidetector CT (MDCT) angiography. Both V/Q SPECT and MDCT angiography seem to have high diagnostic accuracy. However, only limited data directly comparing these 2 modalities are available. Hybrid gamma-camera/MDCT systems have been introduced and allow simultaneous 3-dimensional lung V/Q SPECT and MDCT angiography, suitable for diagnosing PE. The aim of our study was to compare, in a prospective design, the diagnostic ability of V/Q SPECT, V/Q SPECT combined with low-dose CT, and pulmonary MDCT angiography obtained simultaneously using a combined SPECT/MDCT scanner in patients suspected of having PE. METHODS Consecutive patients from June 2006 to February 2008 suspected of having acute PE were referred to the Department of Nuclear Medicine at Rigshospitalet or Frederiksberg Hospital, Denmark, for V/Q SPECT as a first-line imaging procedure. The number of eligible patients was 196. Patients with positive D-dimer results (>0.5 mmol/mL) or a clinical assessment with a Wells score greater than 2 were included and underwent V/Q SPECT, low-dose CT, and pulmonary MDCT angiography in a single session. Patient follow-up was 6 mo. RESULTS A total of 81 simultaneous studies were available for analysis, of which 38% were from patients with PE. V/Q SPECT had a sensitivity of 97% and a specificity of 88%. When low-dose CT was added, the sensitivity was still 97% and the specificity increased to 100%. Perfusion SPECT with low-dose CT had a sensitivity of 93% and a specificity of 51%. MDCT angiography alone had a sensitivity of 68% and a specificity of 100%. CONCLUSION We conclude that V/Q SPECT in combination with low-dose CT without contrast enhancement has an excellent diagnostic performance and should therefore probably be considered first-line imaging in the work-up of PE in most cases.
منابع مشابه
Comparison of Image Quality of Low Voltage 64-slice Multidetector CT Angiography with the Standard Condition in Patients Suspected of Pulmonary Embolism
Introduction: Reduction of peak kilovoltage (kV) setting has been a useful approach to d creating radiation dose; however, it may have varied effects on noise and the accuracy of diagnosis. Thus, we compared image quality between low (80 kV) and standard kilovoltage (100 kV) protocols. Material and Methods: This triple blind non-randomized parallel quasi-experimental study was conducted on 140 ...
متن کاملV/Q scanning using SPECT and SPECT/CT.
Planar ventilation-perfusion (V/Q) scanning is often used to investigate pulmonary embolism; however, it has well-recognized limitations. SPECT overcomes many of these through its ability to generate 3-dimensional imaging data. V/Q SPECT has higher sensitivity, specificity, and accuracy than planar imaging and a lower indeterminate rate. SPECT allows for new ways to display and analyze data, su...
متن کاملCombined Radionuclide Phlebography and V/Q scan in the assessment of iliac vein thrombosis and pulmonary embolism – A case report establishing a cause and effect relationship
Deep vein thrombosis (DVT) is an important life threatening condition that is difficult to diagnose, particularly in the early stages. Looking for DVT in lower limb can be considered ancillary in suspected cases of pulmonary embolism (PE) indirectly highlighting a cause and effect relationship of a single disease (i.e cause being DVT and effect is the assault on the lung vasculature). Prompt an...
متن کاملThe Utility of Hybrid SPECT/CT Lung Perfusion Scintigraphy in Pulmonary Embolism Diagnosis
Background: Pulmonary embolism (PE) is diagnosed either by ventilation/perfusion (V/Q) scintigraphy or pulmonary CT angiography. One of the imaging methods used in nuclear medicine is hybrid SPECT/CT scintigraphy. Objectives: The aim of this study was to evaluate the utility of SPECT/CT(Q) scintigraphy in the diagnosis of PE and to compare SPECT/ CT(Q) with planar(Q) and SPECT(Q) methods. Metho...
متن کاملThe benefit of personalized hybrid SPECT/CT pulmonary imaging.
Hybrid pulmonary imaging in the present day has seen a fusion of various uses of CT scans, including angiography (CTAG), diagnostic CT, low dose CT (LDCT), and perfusion or ventilation scintigraphy in tomographic or planar imaging. Determining the most effective individualized test for the complete diagnostics of patients with pulmonary symptoms for various groups of patients is a major issue. ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 50 12 شماره
صفحات -
تاریخ انتشار 2009