A disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.

نویسندگان

  • Jie Wu
  • Feng Yan
  • Jinhai Tang
  • Chun Zhai
  • Huangxian Ju
چکیده

BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 as model analytes in a redox mediator-grafted, biopolymer-modified, screen-printed carbon electrode array to capture corresponding horseradish peroxidase-labeled antibodies in competitive immunoreactions. The simultaneous multianalyte immunoassay was automatically carried out to amperometrically monitor the mediator-catalyzed enzymatic response to hydrogen peroxide, which decreased in proportion to the concentrations of analytes in samples. RESULTS The multianalyte immunosensor array had a throughput of 60 samples/h and allowed simultaneous detection of carcinoembryonic antigen, alpha-fetoprotein, beta-human choriogonadotropin, and carcinoma antigen 125 in clinical serum samples with concentrations up to 188 microg/L, 250 microg/L, 266 IU/L, and 334 kIU/L, respectively. The detection limits (limits of the blank, mean of blank plus 3 SD) were 1.1 micro/L, 1.7 microg/L, 1.2 IU/L, and 1.7 kIU/L. The inter- and intraassay imprecision (CVs) of the immunosensor arrays were <7.8% and <9.0%, respectively. The immunosensor arrays were stable for 28 days. CONCLUSIONS This newly constructed immunosensor array provides a simple, automated, simultaneous multianalyte immunoassay with high throughput, short analytical time, and sufficiently low detection limits for clinical application. This method offers the capability of miniaturizing the multianalyte detection device.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Electrochemical stripping analysis of nanogold label-induced silver deposition for ultrasensitive multiplexed detection of tumor markers.

A multiplexed electrochemical immunoassay method was developed for simultaneous ultrasensitive measurement of tumor markers based on electrochemical stripping analysis of silver nanoparticles (Ag NPs). The Ag NPs were deposited on a disposable immunosensor array with a reduction reaction catalyzed by nanogold labels. The immunosensor array was prepared by covalently immobilizing capture antibod...

متن کامل

Disposable immunosensor array for ultrasensitive detection of tumor markers using glucose oxidase-functionalized silica nanosphere tags.

An ultrasensitive multiplexed electrochemical immunoassay method was developed for the detection of tumor markers by combining a newly designed trace tag and a disposable immunosensor array. The array was prepared by immobilizing capture antibodies on gold nanoparticles which were assembled on carbon nanotubes-chitosan modified screen-printed carbon electrodes. The trace tag was prepared by loa...

متن کامل

Disposable reagentless electrochemical immunosensor array based on a biopolymer/sol-gel membrane for simultaneous measurement of several tumor markers.

BACKGROUND A reagentless sensor array for simultaneous multianalyte testing (SMAT) may enable accurate diagnosis and be applicable for point-of-care testing. We developed a disposable reagentless immunosensor array for simple immunoassay of panels of tumor markers. METHODS We carried out SMAT with a direct capture format, in which colloidal gold nanoparticles with bound horseradish peroxidase...

متن کامل

Sensitive electrochemical immunosensor array for the simultaneous detection of multiple tumor markers.

A novel electrochemical immunosensor array for the simultaneous detection of multiple tumor markers was developed by incorporating electrochemically addressing immobilization and one signal antibody strategy. As a proof-of-principle, an eight-electrode array including six carbon screen-printed working electrodes was used as a base array for the analysis of two important tumor markers, carcinoem...

متن کامل

Fabrication of an Electrochemical Immunosensor for Determination of Human Chorionic Gonadotropin Based on PtNPs/Cysteamine/AgNPs as an Efficient Interface

An ultrasensitive electrochemical immunosensor for the detection of tumor marker human chorionic gonadotropin (hCG) was developed with a limit of detection as low as 2 pg mL-1 in phosphate buffer. The Platinum nanoparticles (PtNPs) were electrodeposited to modify the gold surface and to increase enlarging the electrochemically active sites, resulting in the facilitation of electron exchange. Cy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical chemistry

دوره 53 8  شماره 

صفحات  -

تاریخ انتشار 2007