Assessment of tear film dynamics: quantification approach.

نویسندگان

  • Alan Tomlinson
  • Santosh Khanal
چکیده

The dynamics of the tear film are reviewed with specific reference to the biophysical aspects: distribution, turnover and elimination through evaporation, drainage, and absorption. The review concentrates on quantitative assessments and is confined to aspects of the dynamics that can be fully and directly measured. The techniques of fluorophotometry, fluorescein clearance, lacrimal scintigraphy, evaporimetry and osmometry are described. Reports in the literature for values of tear turnover (flow), evaporation and osmolarity for normal and dry eyes are collated. Indices of tear film dynamics based on these measurements, including tear function index, total tear flow, and osmolarity, are discussed in relation to their potential in the differential diagnosis of dry eye and new referent values for the disease suggested. The limitations of derivation and application of these indices are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Changes in aberrations and retinal image quality due to tear film dynamics.

A reliable and objective method to measure aberration changes due to the tear film is essential in improving clinical assessment of the tear film and in vivo retinal imaging. The tear film of 11 subjects are studied by acquiring continuous wavefront measurements in real-time with a customized Shack-Hartmann wavefront sensor. The device has a high resolution lenslet array (190 mum) and a topogra...

متن کامل

Automatic dynamic tear meniscus measurement in optical coherence tomography

An image processing algorithm is developed for quantitative assessment of tear meniscus dynamics from continuous optical coherence tomography (OCT) measurements. Clinical utility of dynamic OCT tear meniscus measurement is assessed in studies of tear meniscus parameters. The results indicate that any apparent changes in the early post-blink phase meniscus parameters are essentially related to t...

متن کامل

Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

PURPOSE To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Evaluation of diagnostic test or technology. METHODS Dynamic recording of double-pass retinal images during unforced tear-film break...

متن کامل

Dynamics and function of the tear film in relation to the blink cycle.

Great strides have recently been made in quantitative measurements of tear film thickness and thinning, mathematical modeling thereof and linking these to sensory perception. This paper summarizes recent progress in these areas and reports on new results. The complete blink cycle is used as a framework that attempts to unify the results that are currently available. Understanding of tear film d...

متن کامل

Introducing a new parameter for the assessment of the tear film lipid layer.

PURPOSE The differential diagnosis of dry eye syndrome is still a challenging task. The purpose of this study was to understand the relationship between a novel, objective clinical parameter, the "corrected lipid layer stabilization time," and commonly performed clinical tests for dry eye patients. METHODS Data were obtained from a prospective clinical study with 59 patients of different subj...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The ocular surface

دوره 3 2  شماره 

صفحات  -

تاریخ انتشار 2005