Measurement of energy dependence for XRCT radiochromic film.

نویسندگان

  • Martin J Butson
  • Tsang Cheung
  • Peter K N Yu
چکیده

Gafchromic XRCT, radiochromic film is assessed over a broad energy range, from kilovoltage to megavoltage x rays for variations in reflected optical density to dose response. A large energy dependence was found with reflected optical density output for the same delivered dose varying from 7.8±0.35 at 25.5keV (50kVp) peaking at 12.1±0.5 at 54keV (125kVp) to 0.975±0.03 at 2300keV (10MV) when normalized to 1 at 1400keV (6MV) energy. The response is constant (within 3%) in the 36-69keV equivalent photon energy range, which corresponds to x-ray tube generating potentials of approximately 100-150kVp. This matches well with beam qualities for diagnostic computed topography applications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Absorption spectra of irradiated XRCT radiochromic film.

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes colour upon irradiation changing from a yellow to green/brown colour. The absorption spectra of Gafchromic XRCT radiochromic film a...

متن کامل

Computed Tomography Dosimeter Utilizing a Radiochromic Film and an Optical Common-mode Rejection Characterization and calibration of the GafChromic XRCT film

Gafchromic XRCT radiochromic film is a self-developing high sensitivity radiochromic film product which can be used for assessment of delivered radiation doses which could match applications such as computed tomography (CT) dosimetry. The film automatically changes color upon irradiation changing from amber to dark greenish-black depending on the level of exposure. The absorption spectra of Gaf...

متن کامل

Enhancement of MD-55-2 radiochromic film sensitivity using a multilayer film technique for applications in the low dose range

 ABSTRACTBackgrounds: MD-55-2 is one of the Radiochromic film models with the sensitivity suitable for dose measurements ranging from 5 to 100 Gy.  However, this lower limit makes the film impractical for its applications in many areas such as brachytherapy source dosimetry.Materials and methods: In this project, the useful range of the film has been extended by using a multilayer film techniqu...

متن کامل

Dosimetric comparison between XR-RV3 and EBT2 radiochromic film in megavoltage photon beams

Background:  Radiochromic film is used for radiation dose measurement, XR-RV3 is used in fluoroscopy and EBT2 film in radiation therapy. The aim was to determine if the dosimetric properties of these two films are comparable in megavolt photon beams. Materials and Methods: Comparison measurements included: calibration curves, heterogeneous phantom dose profiles, and nasopharynx dose distributio...

متن کامل

Rounded end multi-leaf penumbral measurements with radiochromic film.

Multi-leaf penumbral doses have been investigated for 6 MV x-rays and a Varian millennium multi-leaf collimator (MLC) using Gafchromic MD-55-2, radiochromic film and X-omat V radiographic film. An advantage of Gafchromic film for multi-leaf penumbral dose measurement is the relatively low energy dependence of the film. A comparison of penumbral dose measurements has also ascertained the effects...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical physics

دوره 33 8  شماره 

صفحات  -

تاریخ انتشار 2006