ISSCC 2016 / SESSION 26 / WIRELESS FOR IoE / 26 . 7 26 . 7 A 10 mm 3 Syringe - Implantable Near - Field Radio System on Glass Substrate
نویسندگان
چکیده
We present a millimeter-scale near-field radio system for ultra-low-power (ULP) healthcare sensor nodes. It is specifically designed for ‘syringe implantation’ which minimizes invasiveness of implantation. Designing a millimeter-scale wireless node for implanted healthcare is challenging because: 1) the antenna is constrained to the diameter of the syringe needle, which significantly constrains the link distance through RF. 2) The energy/power are strictly limited by the millimeter-scale form-factor where thin-film batteries can source only <10μAh and sustain <50μA peak current. Recent works [1-4] have demonstrated nearfield transceivers for millimeter-scale implants. Passive backscatter radios consume low power but they are only operable at very short distances (e.g., 3.5cm) due to excessive path loss and self-jamming at the reader [1-2]. Although active radios can provide >10cm distance, their high power consumption (45mW [3]) and/or large antenna size (2.3cmx2.4cm [4]) make them impractical for implanted healthcare applications.
منابع مشابه
WIRELESS FOR IoE / 26 . 7 26 . 7 A 10 mm 3 Syringe - Implantable Near - Field Radio System on Glass Substrate
We present a millimeter-scale near-field radio system for ultra-low-power (ULP) healthcare sensor nodes. It is specifically designed for ‘syringe implantation’ which minimizes invasiveness of implantation. Designing a millimeter-scale wireless node for implanted healthcare is challenging because: 1) the antenna is constrained to the diameter of the syringe needle, which significantly constrains...
متن کاملA 10 mm3 Inductive Coupling Radio for Syringe-Implantable Smart Sensor Nodes
We present a near-field radio system for a millimeter-scale wireless smart sensor node that is implantable through a 14-gauge syringe needle. The proposed system integrates a radio system on chip and a magnetic antenna on a glass substrate within a total dimension of 1 × 1 × 10 mm3. We demonstrate energy-efficient active near-field wireless communication between the millimeter-scale sensor node...
متن کاملCan amiodarone induce hyperglycaemia and hypertriglyceridaemia?
Old BS 1619 2 ml glass insulin syringe (U20 insulin) + 26 gauge, 0-5 inch needle 1-26 (U20), (Everett) 0-063 2-52 (U40) New BS 1619 1 ml glass insulin syringe (UIOO insulin) + 26 gauge, 0-5 inch needle (Rand Rocket) 0-051 5 1 (UIOO) New BS 1619 0 5 ml glass insulin syringe (UI00 insulin) + 26 gauge, 0-5 inch needle (Rand Rocket) 0-05 5 (U100) BD Plastipak 1 ml plastic disposable syringe (U100 i...
متن کاملStructural and optical properties of ZnS thin films deposited by RF magnetron sputtering
Zinc sulfide [ZnS] thin films were deposited on glass substrates using radio frequency magnetron sputtering. The substrate temperature was varied in the range of 100°C to 400°C. The structural and optical properties of ZnS thin films were characterized with X-ray diffraction [XRD], field emission scanning electron microscopy [FESEM], energy dispersive analysis of X-rays and UV-visible transmiss...
متن کاملCerebrotendinous xanthomatosis: a defect in mitochondrial 26-hydroxylation required for normal biosynthesis of cholic acid.
Oxidation of side chain of 5 beta-cholestane-3 alpha,7 alpha,12 alpha-triol was studied in a patient with cerebrotendinous xanthomatosis (CTX) and in control subjects, using various subcellular fractions of liver homogenate and a method based on isotope dilution-mass spectrometry. In the control, 5 beta-cholestane-3 alpha,7 alpha,12 alpha-triol was converted into 5 beta-cholestane-3 alpha,7 alp...
متن کامل