Attenuation correction of myocardial perfusion SPET in patients of normal body mass index.
نویسندگان
چکیده
Soft tissue attenuation artefacts are more likely to occur in patients with high body mass index (BMI) undergoing myocardial perfusion imaging (MPI) and therefore it is routine practice in our department to perform attenuation correction in this group of patients. However, we suspected that attenuation artefacts may also occur in patients with normal BMI. We collected data prospectively on 57 patients with BMI less than 25kg/m(2) who underwent stress-rest MPI single photon emission tomography (SPET) as part of their standard management at our institution. The differences between the attenuation corrected (AC) and non attenuation corrected (NC) images were evaluated by two experienced readers blinded to patient gender and clinical details. Visual improvement in perfusion with attenuation correction was seen in 54.4% of patients with normal BMI and was more common in males (84.2%) than females (39.5%). Discordances between AC and NC were most frequent in the inferior, inferolateral and anteroseptal segments in both males and females and were also seen in the apical and anterior segments in some patients, mainly in females, in keeping with the well-recognized distribution pattern for attenuation artefacts. In conclusion, although a small sample size was used in this study, changes in appearance with attenuation correction likely to represent attenuation artefacts were seen in 54.4% of patients with normal BMI and were two times more common in males than females. These changes were felt to be clinically relevant in that they could lead to a change in the final report and may ultimately affect the diagnosis and clinical management. Thus, attenuation correction could be of value in patients of normal BMI. Further larger studies with correlation with clinical follow-up or invasive coronary angiography are warranted.
منابع مشابه
Attenuation correction in myocardial perfusion SPECT using sequential transmission - emission scanning with 99mTc [Persain]
Introduction: Nowadays, Imaging of the myocardial perfusion (MPI) using the single photon emission tomography (SPET) in the diagnosis of coronary artery disease, especially myocardial ischemia, is of great importance. In contrast to the coronary artery angiography, MPI is non-invasive, less expensive and more physiological. Unfortunately, this image is affected by the some artifacts. Thes...
متن کاملEvaluation of attenuation correction process in cardiac SPECT images
Introduction: Attenuation correction is a useful process for improving myocardial perfusion SPECT and is dependent on activity and distribution of attenuation coefficients in the body (attenuation map). Attenuation artifacts are a common problem in myocardial perfusion SPECT. The aim of this study was to compare the effect of attenuation correction using different a...
متن کاملComparison of plasma leptin levels in patients with normal, low and high risk myocardial perfusion scan [Persian]
Introduction: Leptin, secreted from adipose tissue may have some correlation with coronary artery disease according to some reports in literature. The mean concentration of plasma leptin in patients with normal and abnormal myocardial perfusion imaging (MPI) and relation of leptin levels, independently to abnormality in MPI after correction for body mass index (BMI) was evaluated. Methods...
متن کاملComparison of transient ischemic dilation ratios in SPECT and SPECT-CT myocardial perfusion imaging in the low pre-test probability group
Introduction: The main purpose of this study was to compare transient ischemic dilation (TID) ratios in SPECT-low dose CT and SPECT Myocardial Perfusion Imaging (MPI) by application of different quantitative programs and quantify the possible shift in the upper normal limits of TID ratio in the SPECT-CT MPI. Methods: 149 Patients with low pre-test probability for coronary artery disease (CAD),...
متن کاملMyocardial perfusion imaging parameters: IQ-SPECT and conventional SPET system comparison.
Technological advancement in hardware and software development in myocardial perfusion imaging (MPI) leads to the shortening of acquisition time and reduction of the radiation burden to patients. We compared semiquantitative perfusion results and functional parameters of the left ventricle between new dedicated cardiac system with astigmatic collimators called IQ-SPECT (Siemens Medical Solution...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Hellenic journal of nuclear medicine
دوره 15 3 شماره
صفحات -
تاریخ انتشار 2012