Comparison of a limited computerized diagnostic system (ResCare Autoset) with polysomnography in the diagnosis of obstructive sleep apnoea syndrome.

نویسندگان

  • J L Kiely
  • C Delahunty
  • S Matthews
  • W T McNicholas
چکیده

The increasing numbers of patients referred for evaluation of suspected obstructive sleep apnoea (OSA) places a growing burden on available sleep laboratory resources. A number of limited diagnostic systems have been developed in an effort to cope with this clinical problem. In this study, the diagnostic capabilities of one limited diagnostic system (ResCare Autoset) were compared with full polysomnography (PSG), using the Oxford SAC computerized system. Thirty six patients with suspected OSA had simultaneous studies performed both with the Autoset and Oxford PSG systems. The apnoea plus hypopnoea index (AHI) (events x h(-1)) scored by the Autoset system was compared with the AHI scored from the PSG raw tracings by an experienced sleep technician. There were highly significant correlations between the Autoset AHI and the AHI scored by the manual PSG scoring method (r=0.92; p<0.001). The positive predictive value for diagnosis of OSA for the Autoset was 86% when compared with manual PSG scoring, based on an AHI threshold for OSA of 15 events x h(-1). However, the agreement between Autoset and PSG was poor in severe cases of OSA, although not sufficiently so as to result in mistaken diagnosis in any of these cases. We conclude that the Autoset system is a sensitive and easy to use system, which facilitates screening for obstructive sleep apnoea with a reasonable degree of accuracy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of polysomnography with ResCare Autoset in the diagnosis of the sleep apnoea/hypopnoea syndrome.

BACKGROUND Increasing referral numbers make the development of simplified accurate methods of diagnosing the sleep apnoea/hypopnoea syndrome highly desirable. The accuracy of one such system--the ResCare Autoset--has been examined. METHODS Thirty one consecutive patients assessed by polysomnography had simultaneous monitoring of their respiratory pattern using the Autoset system. The Autoset ...

متن کامل

Comparison of ResMed AutoSet (version 3.03) with polysomnography in the diagnosis of the sleep apnoea/hypopnoea syndrome.

In patients with the sleep apnoea/hypopnoea syndrome (SAHS), accurate and timely diagnostic evaluation and initiation of effective treatment is important. Therefore, an increasing number of limited sleep studies are now performed nowadays diagnosing the SAHS in typical patients. It was the aim of the present study to evaluate the diagnostic accuracy of one such system, the updated ResMed Sulliv...

متن کامل

Accuracy of an intelligent CPAP machine with in-built diagnostic abilities in detecting apnoeas: a comparison with polysomnography.

BACKGROUND In patients with sleep apnoea early diagnostic evaluation and treatment may be delayed due to limited access to full polysomnography (PSG). For "typical" patients, simplified strategies are needed. A study was performed to evaluate the accuracy of a new continuous positive airway pressure (CPAP) device with in-built diagnostic abilities (Autoset) in detecting apnoeas. METHODS Twent...

متن کامل

Simultaneous laboratory-based comparison of ResMed Autoset with polysomnography in the diagnosis of sleep apnoea/hypopnoea syndrome.

ResMed Autoset (AS) is a simplified diagnosis system for obstructive sleep apnoea/hypopnoea syndrome (OSAS) based on the respiratory flow/time relationship by pressure variation measured through simple nasal prongs. A multicentre prospective trial was used to compare AS and polysomnography (PSG) for diagnosing 95 patients, with suspected OSAS. Physicians gave a pretest probability of the patien...

متن کامل

Automatic CPAP titration with different self-setting devices in patients with obstructive sleep apnoea.

Autotitrating continuous positive airway pressure (CPAP) devices automatically adjust the pressure according to upper airway obstructions. The aim of this study was to compare the treatment effects of different automatic CPAP devices (AutoSet, Horizon and Virtuoso) with conventional CPAP in patients with obstructive sleep apnoea independently of financial manufacturer support. Twelve male patie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The European respiratory journal

دوره 9 11  شماره 

صفحات  -

تاریخ انتشار 1996