Human Reliability Analysis of Cataract Surgery.

نویسندگان

  • Vinod Gauba
  • Peter Tsangaris
  • Charalambos Tossounis
  • Arijit Mitra
  • Chris McLean
  • George M Saleh
چکیده

OBJECTIVE To evaluate the use of the Human Reliability Analysis of Cataract Surgery tool to identify the frequency and pattern of technical errors observed during phacoemulsification cataract extraction by surgeons with varying levels of experience. DESIGN Observational cohort study. Thirty-three consecutive phacoemulsification cataract operations were performed by 33 different ophthalmic surgeons with varying levels of operative experience: group 1, fewer than 50 procedures; group 2, between 50 and 250 procedures; and group 3, more than 250 procedures. Face and content validity were surveyed by a panel of senior cataract surgeons. The tool was applied to the 33 randomized and anonymous videos by 2 independent assessors trained in error identification and correct tool use. Task analysis using 10 well-defined end points and error identification using 10 external error modes were performed for each case. The main outcome measures were number of errors performed per task, nature of performed errors (executional or procedural), and surgical experience of operating surgeon. RESULTS Analysis of 330 constituent steps of 33 operations identified 228 errors, of which 151 (66.2%) were executional and 77 (33.8%) were procedural. The overall highest error probability was associated with sculpting, followed by fragmentation of the nucleus; this was most evident in group 1. Surgeons in group 3 proportionally performed more errors during removal of soft lens matter than those in group 1 or 2. Surgical experience had a significant effect on the number of errors, with a statistically significant difference among the 3 groups (P < .001). CONCLUSIONS The Human Reliability Analysis of Cataract Surgery tool is useful for identifying where technical errors occur during phacoemulsification cataract surgery. The study findings, including the high executional error rate, could be used to enhance and structure resident surgical training and future assessment tools. Face, content, and construct validity of the tool were demonstrated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی خطاهای انسانی در فرایند جراحی آب مروارید چشم با استفاده از تکنیک SHERPA

  Introduction: Human errors result in numerous accidents in healthcare professions every year and lead to the death of many patients. Considering the high rate of eye cataract surgeries performed in Iran and the sensitive nature of the surgery, the present study was conducted to identify and assess possible human errors in the performance of these surgeries. Materials and Method...

متن کامل

Investigation of visual acuity and residual refractive error after cataract surgery in patients with senile cataract by phacoemulsification

Background and Aim: Vision improvement and reduction of refractive errors are considered as important goals of cataract surgery. The purpose of this study was to evaluate residual refractive errors after cataract surgery in the patients with senile cataract in Shahid Rahimi Hospital in Khorramabad City between 2017 and 2018. Material and Methods: This cross-sectional study included 178 patients...

متن کامل

VALUE BASED OPHTHALMOLOGY Quality of care from the perspective of the cataract patient: the reliability and validity of the QUOTE-Cataract

Background/aims: To assess reliability and validity of the QUOTE-cataract, a questionnaire that measures the quality of care from the perspective of cataract patients. Methods: The QUOTE-cataract was tested in a multicentre study among 540 cataract patients in three different hospitals. Reliability was represented by internal consistency (Cronbach’s α), and repeatability (intraclass correlation...

متن کامل

Assessment of the probability of human error occurring in the process of appendectomy operation using SPAR-H method

1.Ochr('39')Connor PO, Keogh IJ. Addressing human error within the Irish healthcare system. Irish Medical Journal. 2011;104(1):5-6. 2. Jahangiri M, Hoboubi N, Rostamabadi A, Keshavarzi S, Hosseini AA. Human error analysis in a permit to work system: a case study in a chemical plant. Safety and Health  at Work. 2016;7(1):6-11. 3. Edmondson AC. Learning from mistakes is easier said than done: G...

متن کامل

Quality of care from the perspective of the cataract patient: the reliability and validity of the QUOTE-cataract.

BACKGROUND/AIMS To assess reliability and validity of the QUOTE-cataract, a questionnaire that measures the quality of care from the perspective of cataract patients. METHODS The QUOTE-cataract was tested in a multicentre study among 540 cataract patients in three different hospitals. Reliability was represented by internal consistency (Cronbach's alpha), and repeatability (intraclass correla...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Archives of ophthalmology

دوره 126 2  شماره 

صفحات  -

تاریخ انتشار 2008