Drug eluting stents: are human and animal studies comparable?
نویسندگان
چکیده
Animal models of stenting probably predict human responses as the stages of healing are remarkably similar. What is characteristically different is the temporal response to healing, which is substantially prolonged in humans. The prevention of restenosis in recent clinical trials of drug eluting stents may represent a near absent or incomplete phase of intimal healing. Continued long term follow up of patients with drug eluting stents for major adverse cardiac events and angiographic restenosis is therefore imperative.
منابع مشابه
Drug-eluting stents: results, promises and problems.
In-stent restenosis is the major drawback of percutaneous coronary interventions, occurring in 10-40% of the patients. Recently, new stents have emerged which are loaded with anti-inflammatory, anti-migratory, anti-proliferative or pro-healing drugs. These drugs are supposed to inhibit inflammation and neointimal growth and subsequently in-stent restenosis. In this review article the results of...
متن کاملDrug-eluting stents: new era and new concerns.
At present there is much excitement about drug-eluting stents, which hold promise for the treatment of coronary artery disease. This ingenious therapy involves coating the outside of a standard coronary stent with a thin polymer containing medication that can prevent scarring at the site of coronary intervention. Early trials with sirolimus coated stents showed that they might prevent coronary ...
متن کاملSecond Generation Drug-Eluting Stents: A Review of the Everolimus-Eluting Platform
Everolimus-eluting stents (EES) represent the next generation of drug-eluting stents (DES). Important design modifications include thin strut stent backbones, less inflammatory and more biocompatible polymers, and lower drug dosing. The cobalt chromium EES fluoropolymer XIENCE V stent has been the most extensively studied of such stents. In animal models, this stent demonstrated minimal vessel ...
متن کاملAn advection-diffusion multi-layer porous model for stent drug delivery in coronary arteries
Arterial drug concentration distribution determines local toxicity. The safety issues dealt with Drug-Eluting Stents (DESs) reveal the needs for investigation about the effective factors contributing to fluctuations in arterial drug uptake. The current study focused on the importance of hypertension as an important and controversial risk factor among researchers on the efficacy of Heparin-Eluti...
متن کاملEstrogen-Eluting Stents
Coronary stenting is routinely utilized to treat symptomatic obstructive coronary artery disease. However, the efficacy of bare metal coronary stents has been historically limited by restenosis, which is primarily due to excessive neointima formation. Drug-eluting stents (DES) are composed of a stainless steel backbone encompassed by a polymer in which a variety of drugs that inhibit smooth mus...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Heart
دوره 89 2 شماره
صفحات -
تاریخ انتشار 2003