Electroacupuncture interferes with bispectral index monitoring.
نویسندگان
چکیده
As we were interested in the use of bispectral index (BIS) monitoring during the application of acupuncture, we conducted a PubMed search on 31 July 2012 using the keywords ‘acupuncture’ and ‘bispectral index’. This yielded 23 articles reporting the use of BIS during evaluation of the effects of acupuncture. Except for the paper by Zheng et al recently published in this journal, none of these articles mentioned the possible interaction of the acupuncture point stimulation procedure with EEG, which is the primary signal used in the BIS algorithm for monitoring the depth of anaesthesia. We present a clinical case which supports the concerns of Zheng et al on the influence of electroacupuncture (EA) on EEG. After giving informed consent, a 73-year-old woman received auricular EA during elective extracranial skin surgery. Total intravenous anaesthesia was induced and maintained with propofol (4–8 mg/kg/h), and the opioid analgesic sufentanil was given in a total dose of 50 mg during 140 min of anaesthesia to blunt noxious responses and keep the heart rate and blood pressure within 20% of the baseline level. The patient did not receive any other drugs which might have influenced the EEG signal during EA and BIS monitoring. The airway was secured with an endotracheal tube and lung ventilation was mechanically controlled to keep endtidal carbon dioxide at 4.5–5.3 kPa. The depth of anaesthesia was measured using a BIS IntelliVue MP70 monitor (Philips Medical Systems, Germany). The body temperature was maintained within 1°C of the baseline level. Two steel needles 0.22×13 mm (Vinco, China) were inserted 1.5 cm apart at the auricular concha ipsilateral to the attached BIS sensor. Stimulation was applied using the PuntoBravo device (MTR GmbH, Germany) yielding biphasic rectangular impulses with a length of 200 ms, intensity of 5 mA and varying frequencies (figure 1). As a result, EA caused clear changes in the raw EEG curve which is used for BIS calculation. The signal quality index (SQ on figure 1) decreased and electromyographic activity (EMG) and burst suppression index increased during EA compared with no stimulation (upper curve on figure 1). It is known that even smaller artefacts introduced by EMG or electric devices into raw EEG may be misinterpreted by the BIS algorithm as cerebral activity and thus lead to falsely high BIS values. We observed EEG artefacts under EA with 5 mA applied to the concha of the ear—that is, remote from the BIS sensor where acquisition of the EEG signal takes place. We presume that the stimulation of acupuncture points VG24 and Yintang (vicinity to BIS sensor) with
منابع مشابه
Impact of Bispectral Index Monitoring Versus Clinical Judgment as a Guide for Conduction of Anesthesia on Serum Cortisol Level in Co-ronary Artery Bypass Graft Surgery
Background: Inadequate depth of anesthesia leads to release of stress hormones. Electroencephalographic monitoring by bispectral index is a guide to asses the depth of anesthesia. The aim of the present study was to measure the serum cortisol levels as an index of stress response in patients who are candidates for coronary artery bypass graft surgery in two groups of patients. Methods: Seventy-...
متن کاملElectroacupuncture reduces the dose of midazolam monitored by the bispectral index in critically ill patients with mechanical ventilation: an exploratory study.
OBJECTIVE Electroacupuncture, a modern variation on a traditional Chinese treatment, might be useful for sedation and analgesia. This study aims to investigate whether electroacupuncture can modify the dose of midazolam monitored by the bispectral index (BIS) in critically ill patients with mechanical ventilation. METHODS Orotracheally intubated patients undergoing mechanical ventilation were...
متن کاملThe Utility of Bispectral Index for Titration of Propofol Dosages and Recovery from Anaesthesia
Background: The use of clinical signs may not be reliable to measure the hypnotic component of anaesthesia. Bispectral Index monitoring provides a direct measurement of the hypnotic effect of the anaesthetic agent used and it may have certain clinical advantages over clinical signs. Objective: This study consists of dose requirement of propofol with bispectral Index monitoring and without bispe...
متن کاملInterruption of bispectral index monitoring by nerve integrity monitoring during tympanoplasty -A case report-
We report that intraoperative NIM-2 monitoring devices can interfere with bispectral index monitoring. A 45-year-old male with chronic otits media underwent tympanolasty under general anesthesia with NIM-2 monitoring and bispectral index monitoring at our institution. And then, bispectral index monitoring was severely interrupted by facial nerve monitoring.
متن کاملBispectral index detects intraoperative cerebral ischaemia during balloon assisted cerebral aneurysm coiling
Bispectral index (BIS) is a monitoring modality designed and used for monitoring depth of anaesthesia. We wish to report a case where BIS monitoring may have alerted us to a potential adverse neurological event during angiographic coiling of a cerebral aneurysm.
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Acupuncture in medicine : journal of the British Medical Acupuncture Society
دوره 30 4 شماره
صفحات -
تاریخ انتشار 2012