Saline-Enhanced Hepatic Radiofrequency Ablation Using a Perfused-Cooled Electrode: Comparison of Dual Probe Bipolar Mode with Monopolar and Single Probe Bipolar Modes

نویسندگان

  • Jeong Min Lee
  • Joon Koo Han
  • Se Hyung Kim
  • Jae Young Lee
  • Dae Jin Kim
  • Min Woo Lee
  • Gyung goo Cho
  • Chang Jin Han
  • Byung Ihn Choi
چکیده

OBJECTIVE To determine whether saline-enhanced dual probe bipolar radiofrequency ablation (RFA) using perfused-cooled electrodes shows better in-vitro efficiency than monopolar or single probe bipolar RFA in creating larger coagulation necrosis. MATERIALS AND METHODS RF was applied to excised bovine livers in both bipolar and monopolar modes using a 200 W generator (CC-3; Radionics) and the perfused-cooled electrodes for 10 mins. After placing single or double perfused-cooled electrodes in the explanted liver, 30 ablation zones were created at three different regimens: group A; saline-enhanced monopolar RFA, group B; saline-enhanced single probe bipolar RFA, and group C; saline-enhanced dual probe bipolar RFA. During RFA, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in the impedance currents and liver temperature during RFA were then compared between the groups. RESULTS The mean current values were higher for monopolar mode (group A) than for the bipolar modes (groups B and C): 1550+/-25 mA in group A, 764+/-189 mA in group B and 819+/-98 mA in group C (p < 0.05). The volume of RF-induced coagulation necrosis was greater in group C than in the other groups: 27.6+/-2.9 cm(3) in group A, 23.7+/-3.8 cm(3) in group B, and 34.2+/-5.1 cm(3) in group C (p < 0.05). However, there was no significant difference between the short-axis diameter of the coagulation necrosis in the three groups: 3.1+/-0.8 cm, 2.9+/-1.2 cm and 4.0+/-1.3 cm in groups A, B and C, respectively (p > 0.05). The temperature at 15 mm from the electrode was higher in group C than in the other groups: 70+/- 18 degrees C in group A, 59+/-23 degrees C in group B and 96+/-16 degrees C in group C (p > 0.05). CONCLUSION Saline-enhanced bipolar RFA using dual perfused-cooled electrodes increases the dimension of the ablation zone more efficiently than monopolar RFA or single probe bipolar RFA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparative Experimental Study of the In-vitro Efficiency of Hypertonic Saline-Enhanced Hepatic Bipolar and Monopolar Radiofrequency Ablation

OBJECTIVE To compare the in-vitro efficiency of a hypertonic saline (HS)-enhanced bipolar radiofrequency (RF) system with monopolar RF applications by assessing the temperature profile and dimensions of RF-created coagulation necrosis in bovine liver. MATERIALS AND METHODS A total of 27 ablations were performed in explanted bovine livers. After placement of two 16-gauge open-perfused electrod...

متن کامل

Needle-based ablation of renal parenchyma using microwave, cryoablation, impedance- and temperature-based monopolar and bipolar radiofrequency, and liquid and gel chemoablation: laboratory studies and review of the literature.

BACKGROUND AND PURPOSE Small renal tumors are often serendipitously detected during the screening of patients for renal or other disease entities. Rather than perform a radical or partial nephrectomy for these diminutive lesions, several centers have begun to explore a variety of ablative energy sources that could be applied directly via a percutaneously placed needle-like probe. To evaluate th...

متن کامل

Bipolar radiofrequency ablation of the kidney: comparison with monopolar radiofrequency ablation.

PURPOSE We report initial ex vivo and in vivo studies using bipolar radiofrequency (RF) ablation of porcine kidneys. An internal ground electrode is positioned in the kidney opposite the RF electrode, resulting in ablation of all the intervening renal tissue. MATERIALS AND METHODS Ex vivo preparations of 10 porcine kidneys were perfused continuously with Ringer's solution and treated with eit...

متن کامل

Radio Frequency Ablation in the Rabbit Lung Using Wet Electrodes: Comparison of Monopolar and Dual Bipolar Electrode Mode

OBJECTIVE To compare the effect of radio frequency ablation (RFA) on the dimensions of radio frequency coagulation necrosis in a rabbit lung using a wet electrode in monopolar mode with that in dual electrode bipolar mode at different infusion rates (15 mm/hr versus 30 ml/hr) and saline concentrations (0.9% normal versus 5.8% hypertonic saline). MATERIALS AND METHODS Fifty ablation zones (one...

متن کامل

Hepatic Radiofrequency Ablation Using Multiple Probes: Ex Vivo and In Vivo Comparative Studies of Monopolar versus Multipolar Modes

OBJECTIVE We wanted to compare the efficiency of multipolar radiofrequency ablation (RFA) using three perfused-cooled electrodes with multiple overlapping and simultaneous monopolar techniques for creating an ablation zone in ex vivo bovine livers and in in vivo porcine livers. MATERIALS AND METHODS In the ex vivo experiments, we used a 200 W generator (Valleylab, CC-3 model) and three perfus...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2004