A comprehensive comparison study of three different planar IMRT QA techniques using MapCHECK 2

نویسندگان

  • Vance P. Keeling
  • Salahuddin Ahmad
  • Hosang Jin
چکیده

The purpose of this study is to determine comparability of three different planar IMRT QA techniques: patient gantry angle composite (PGAC), single gantry angle composite (SGAC), and field by field (FBF), using MapCHECK 2 device and the γ test as performance metrics; and to assess the dependency of these techniques on intensity modulation, couch attenuation, and detector position (angular dependency). Ten highly modulated head and neck (H&N) and ten moderately modulated prostate IMRT validation plans were delivered using different techniques and were intercompared using the Student's t-test. The IMRT QA measurements were evaluated by percentage of points passing the γ test for three different criteria: 1% (dose difference)/1 mm (distance to agreement (DTA)) (C1), 2%/2 mm (C2), and 3%/3 mm (C3). To investigate dependency of the IMRT validation on treatment couch, ionization chamber measurements, as well as the conventional MapCHECK 2 QAs, were performed with PGAC and PGAC-WOC (without couch; using an extended tennis racket-type insert with negligible attenuation assumed). To determine angular dependency of the MapCHECK 2, patient gantry field-by-field (PG-FBF) technique was delivered and evaluated separately for each field. The differences of γ passing rates between SGAC and FBF were statistically insignificant, while these were statistically significant when compared to PGAC. SGAC and FBF techniques showed statistically insignificant differences between different levels of intensity modulation (H&N vs. Prostate) at C2 and C3 criteria, while PGAC could not for any criteria. The treatment couch has a significant impact on γ passing rates (PGAC vs. PGAC-WOC), but an ionization chamber-based IMRT validations showed clinically insignificant dose errors (< 2%) in all cases. This study showed that the MapCHECK 2 device has large angular dependency, especially at gantry angles of 90° and 270°, which dramatically affected the γ passing rates of PGAC. With proper consideration of couch attenuation and beam arrangement, the MapCHECK 2 will produce clinically comparable QA results using the three different planar IMRT QA techniques.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of a 2D diode array for IMRT quality assurance.

BACKGROUND AND PURPOSE The QA of intensity modulated radiotherapy (IMRT) dosimetry is a laborious task. The goal of this work is to evaluate the dosimetric characteristics of a new 2D diode array (MapCheck from Sun Nuclear Corporation, Melbourne, Florida) and assess the role it can play in routine IMRT QA. MATERIAL AND METHODS Fundamental properties of the MapCheck such as reproducibility, li...

متن کامل

EPID dosimetry for pretreatment quality assurance with two commercial systems

This study compares the EPID dosimetry algorithms of two commercial systems for pretreatment QA, and analyzes dosimetric measurements made with each system alongside the results obtained with a standard diode array. 126 IMRT fields are examined with both EPID dosimetry systems (EPIDose by Sun Nuclear Corporation, Melbourne FL, and Portal Dosimetry by Varian Medical Systems, Palo Alto CA) and th...

متن کامل

A comparison of the quality assurance of four dosimetric tools for intensity modulated radiation therapy

BACKGROUND This study was designed to compare the quality assurance (QA) results of four dosimetric tools used for intensity modulated radiation therapy (IMRT) and to suggest universal criteria for the passing rate in QA, irrespective of the dosimetric tool used. MATERIALS AND METHODS Thirty fields of IMRT plans from five patients were selected, followed by irradiation onto radiochromic film,...

متن کامل

3D Analysis of Intensity-Modulated Radiation Therapy Quality Assurance Measurement using a 2D Diode Array

Intensity-modulated radiation therapy (IMRT) quality assurance (QA) is often performed using a 2D device and compares measured and computed fluence maps to determine if a field passes or fails certain dose and position criteria. The effects of a measured deviation to the 3D patient spatial dosimetry and dose volume histogram (DVH) are largely unknown because they cannot be analyzed using commer...

متن کامل

A Comparison Study of Volumetric Modulated Arc Therapy Quality Assurances Using Portal Dosimetry and MapCHECK 2

A Varian Portal Dosimetry system was compared to an isocentrically mounted MapCHECK 2 diode array for volumetric modulated arc therapy (VMAT) QA. A Varian TrueBeam STx with an aS-1000 digital imaging panel was used to acquire VMAT QA images for 13 plans using four photon energies (6, 8, 10 and 15 MV). The EPID-based QA images were compared to the Portal Dose Image Prediction calculated in the V...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2013