Cross-sectional Presentation and Basic Operational Principles of 3MV Van de Graaff Accelerator at Atomic Energy Centre, Dhaka

نویسندگان

  • Md. Zakir Hossain
  • Azharul Islam
  • Md. Joynal Abedin
  • Md. Atiqur Rahman
چکیده

In 1964, a positive ion horizontal type Van de Graaff accelerator (KN3000) was installed at Atomic Energy Center, Dhaka (AECD). This accelerator was manufactured by the High Voltage Engineering Corporation, Burlington, Mass., USA. Van de Graaff accelerator consists of a number of operating parts related each other. This accelerator can produce and accelerate 3 MeV proton beam using Hydrogen, Helium, and Deuterium ion source gas. Ion Beam Analytical (IBA) techniques Proton Induced X-ray Emission (PIXE) and Proton Induced Gamma Emission (PIGE) are used for data acquisition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

طراحی و شبیه‌سازی ستون شتابدهنده دوترونی الکترواستاتیکی 2MV

In this paper design and simulation of an optimized accelerator tube is presented for the production of light charged particles up to energy of 2 MeV. Geometry of the accelerator tube electrodes was simulated based on the Van De Graaff accelerator tubes of Atomic Energy Organization by SIMION 7.0, Virtual Device and SIMION Toolkit codes. In accelerator tube, the extracted ion beam from the ion ...

متن کامل

Proton Induced Gamma Emission Method with the 3 mv van de Graaff Accelerator

Proton induced gamma emission (PlGE) method has been developed at the Accelerator Laboratory of Atomic Energy Centre, Dhaka (AECD) for analyzing low Z elements in the range of 3 to 15. With a view to exploiting the potential of PIGE technique as a tool for practical applications, attempts have been made to find the experimental evidence for its capability and scope. Gamma ray yields from PIGE e...

متن کامل

Assessment of whole-body occupational radiation exposures in nuclear medicine practices of Bangladesh during 2010-2014

Introduction: Occupational exposure to ionizing radiation due to medical activities (both diagnostic and therapeutic procedures) has increased sharply in recent years. Among the occupationally exposed workers in these fields, those most affected by this increased exposure to ionizing radiation are nuclear medicine workers. In this study, annual average effective dose, annual collective effectiv...

متن کامل

 Radioactivity of soil at proposed Rooppur Nuclear Power Plant site in Bangladesh

Background: The concentrations and distributions of natural and anthropogenic radioactive materials in soils of the site of Rooppur Nuclear Power Plant (RNPP) were investigated with the aim of evaluating the environmental radioactivity and radiation hazard. Materials and Methods: Soil samples were collected from 40 locations in and around the proposed site of Rooppur Power Plant and determined ...

متن کامل

Diagnosis of dynamitron accelerator faults through the observation of narrow nuclear resonances

2014 Narrow nuclear resonances, initially used to calibrate the energy of the Birmingham Radiation Centre 3MV Dynamitron, have proved useful in discovering and identifying accelerator fault conditions. Short-term energy stability (over e few minutes) of a few tens of eV is common. However, variations of many kV occur for several days before the failure of a thermionic rectifier. The beam energy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015