The correlation of bispectral index with endtidal sevoflurane concentration and haemodynamic parameters in preschoolers.

نویسندگان

  • Mary Ellen McCann
  • Julianne Bacsik
  • Andrew Davidson
  • Susan Auble
  • Lorna Sullivan
  • Peter Laussen
چکیده

BACKGROUND Bispectral index (BIS) is a signal processing device that potentially is a pharmacodynamic measure of the effects of anaesthesia on the central nervous system. METHODS In this prospective blinded study, we investigated the pharmacodynamic relationship between BIS, haemodynamic changes during anaesthesia and endtidal nonsteady state concentrations of sevoflurane in 30 children, mean age 3.3 +/- 1.1 years, who were undergoing tonsillectomy and adenoidectomy. A standardized anaesthetic technique was used and included induction and maintenance with sevoflurane, nitrous oxide and oxygen. BIS, heart rate, mean arterial pressure (MAP) and endtidal sevoflurane (ETsevo) concentrations were continuously recorded and specifically noted at the time of intubation, placement of Dingman gag, incision of adenoid, adenoid out, incision of tonsil, tonsil one out, tonsil two out, last agent off, first spontaneous movement, first eye opening and extubation. The anaesthetist was blinded to BIS throughout the procedure. RESULTS Using a Spearman correlation analysis, there was significant negative correlation between BIS and ETsevo concentrations (r=- 0.888, P < 0.01) and a pharmacodynamic relationship with EC50 (ETsevo at which BIS=50) of 1.48% (95% confidence interval 0.84-2.11). There was a weak negative correlation between sevoflurane and MAP (r=- 0.391, P < 0.01) but no significant correlation between sevoflurane and heart rate. CONCLUSIONS In preschool children undergoing sevoflurane anaesthesia for tonsillectomy and adenoidectomy, endtidal sevoflurane concentrations are more closely correlated with BIS than with MAP or heart rate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Recovery Profiles of Propofol & Sevoflurane Anesthesia with Bispectral Index Monitoring (bis) in General Anesthesia

Background: The aim of the study was to compare the effect of propofol & sevoflurane with respect to hemodynamic changes, recovery profiles and complications in patients scheduled for various elective surgical procedures under general anesthesia. Method: Fifty ASA physical status I-II patients of either sex, aged between 18 and 60 years were randomly divided into two groups to receive either pr...

متن کامل

Influence of age on hypnotic requirement, bispectral index, and 95% spectral edge frequency associated with sedation induced by sevoflurane.

BACKGROUND Aging is associated with a reduction in anesthetic requirements. The effects of age on the electroencephalographic response to inhalational anesthesia have not been well documented. The objective of the present study was to determine the influence of age on hypnotic requirement and electroencephalographic derivatives such as bispectral index and 95% spectral edge frequency associated...

متن کامل

Pregnancy does not enhance volatile anesthetic sensitivity on the brain: an electroencephalographic analysis study.

BACKGROUNDS Parturients are thought to be more sensitive to inhalational anesthetics because their minimum alveolar concentration is decreased. However, this conventional theory may be wrong, because, according to recent animal studies, minimum alveolar concentration indicates anesthetic effect on the spinal cord but not on the brain. The aim of this electroencephalographic study was to investi...

متن کامل

Minimal alveolar concentration of sevoflurane inhibiting the reflex pupillary dilatation after noxious stimulation in children and young adults.

BACKGROUND In children, sevoflurane is the most commonly used anaesthetic. Its excellent haemodynamic tolerance gives it a wide therapeutic index. This halogenated agent can abolish movement [minimal alveolar concentration (MAC)] or haemodynamic responses (MACBAR) to noxious stimulus in children as in adults. Reflex pupillary dilatation (RPD) has been demonstrated as a very sensitive measure of...

متن کامل

Correlation of bispectral index with end-tidal sevoflurane concentration and age in infants and children.

BACKGROUND The bispectral index (BIS) has been evaluated as a tool for measuring depth of anaesthesia, but the use of BIS in a paediatric population is still controversial. This study was designed to evaluate the correlation of BIS with end-tidal sevoflurane concentration and age in infants and children. METHODS Eighty-one patients undergoing elective urology surgery were allocated into three...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Paediatric anaesthesia

دوره 12 6  شماره 

صفحات  -

تاریخ انتشار 2002