Urea and ethylene glycol-facilitated transport systems in the human red cell membrane. Saturation, competition, and asymmetry

نویسندگان

  • R R Mayrand
  • D G Levitt
چکیده

The equilibrium exchange of [14C]urea and ethylene glycol was measured using a new type of fast flow system. Approximately equal volumes of saline and air were mixed to form a segmented fluid stream into which 14C-loaded red cells are injected. The stream flows through three filter chambers which allow sampling of the 14C in the extracellular fluid at three time points. The chambers are designed so that they do not disrupt the segmented bubble pattern. The alternating air and saline segments prevent laminar dispersion in the flowing stream and ensure good mixing at the injection and sampling sites. The equilibrium exchange of both urea and ethylene glycol showed saturation kinetics. The maximum permeability (Po) measured in the limit of zero solute concentration is 1.6 X 10(-3) cm/s for urea and 4.8 X 10(-4) cm/s for ethylene glycol (T = 23 degrees C). The apparent dissociation constant (Km) was 218 mM for urea and 175 mM for ethylene glycol. The Po for thiourea is 2.3 X 10(-6) cm/s and the Km is 19 mM. Urea and thiourea inhibit the transport of each other and the inhibition constant (KI) is approximately equal to the Km for both compounds. 53 other analogues of urea were screened for their inhibition of urea or thiourea transport. Several analogues [e.g., 1-(3,4-dichloro-phenyl)-2-thiourea] had a KI in the range of 0.03 mM. The affinity of the inhibitor increased as it was made more hydrophobic. The urea analogues did not significantly inhibit the ethylene glycol or osmotic permeability. Glycerol inhibited ethylene glycol permeability with a KI of 1,200 mM.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

THE CARRIER FACILITATED TRANSPORT OF THE LITHIUM IONS BY A SERIES OF NON-CYCLIC SYNTHETIC IONOPHORES

The carrier facilitated transport of lithium picrate was studied using a series of non-cyclic polyethers containing different end groups and chain lengths through Bulk Liquid Membrane (BLM) and Supported Liquid Membrane (SLM) systems. The various membrane supports used are viz. PTFE, cellulose nitrate, and dialysis membrane and onion membrane. The amount of Li+ transported depends upon the stru...

متن کامل

Reflection coefficient and permeability of urea and ethylene glycol in the human red cell membrane

The reflection coefficient (sigma) and permeability (P) of urea and ethylene glycol were determined by fitting the equations of Kedem and Katchalsky (1958) to the change in light scattering produced by adding a permeable solute to a red cell suspension. The measurements incorporated three important modifications: (a) the injection artifact was eliminated by using echinocyte cells; (b) the use o...

متن کامل

Tracer Determinations of Human Red Cell Membrane Permeability to Small Nonelectrolytes

A flow system has been used to determine the permeability of human red cell membranes to four small nonelectrolytes labeled with (14)C. The permeability coefficients, omega, in units of mol dyne(-1) sec(-1) x 10(15), are: ethylene glycol, 6; urea, 13; formamide, 22; and methanol, 131. The values for urea and formamide are in good agreement with values obtained by Sha'afi, Gary-Bobo, and Solomon...

متن کامل

Developing of Ethylene Glycol as a New Reducing Agent for Preparation of Pd-Ag/PSS Composite Membrane for Hydrogen Separation

In the present work, for the first time, a palladium-silver membrane has been prepared by electroless plating on the surface of a porous stainless steel disk by using ethylene glycol as a new reducing agent and polyol process. The reducing action of ethylene-glycol in the presence of PVP as a protecting surface agent produces a membrane with finely divided powder and nano-sized pores. Furthermo...

متن کامل

Effect of Ethylene Oxide Functional Groups in PEBA-CNT Membranes on CO2/CH4 Mixed Gas Separation

Poly (ether-block-amide) /poly (ethylene glycol)/ carbon nanotubes mixed matrix membranes have been successfully fabricated using solvent evaporation method to determine the effect of ethylene oxide groups on the performance of produced membranes. The effects of CNTs (2-8 wt%) and PEG (up to 50 wt%)were investigated in both single and mixed gas test setup in different temperature and pressure. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of General Physiology

دوره 81  شماره 

صفحات  -

تاریخ انتشار 1983