Matlab Simulation of Single Phase Shunt Active Filter Based on PQ Theory

نویسندگان

  • Krishna Veer Singh
  • Priyank Bhavsar
چکیده

ABSTRACTThis paper presents the simulation of single phase shunt active filter based on PQ theory. Generally PQ theory is used for 3 phases 3 wires or 3 phases 4 wire system but here it is used for single phase system. This paper also concentrates hardly on reduction of THD of load current. Since the system has only single phase signal for both voltage and current, thus the dummy signal with 120 o different angels must be generated for input of the p-q theory. During simulation the six pulses will be generated for switching of IGBT but only two will be used. MATLAB/SIMULINK power system toolbox is used to simulate the proposed system.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Different Real Time Reference Generation Techniques used for Harmonic Mitigation in Three Phase Shunt Active filters

This paper presents four types of time domain control techniques for generation of real time compensating current with a view to the problem of source current harmonics caused by non-linear loads in three phase three wire shunt active filters. All the techniques are analyzed mathematically and simulation results are compared in terms of compensation performance with multi parameter under steady...

متن کامل

Indirect Control of Single-Phase Active Power Filters using Harmonic Control Arrays

The ever increase of nonlinear loads in electric distribution networks causes many problems due to the high level of harmonic currents. This paper proposes a new technique for controlling a single phase shunt active power filter based on a selective compensation using the newly developed technique of harmonic control arrays. Simulation results confirm the appropriate selective harmonic compensa...

متن کامل

Single-Phase Shunt Active Power Filter Using Indirect Control Method

A single-phase shunt active power filter is used mainly for the elimination of harmonics in single-phase AC networks. In this paper a single-phase shunt active power filter based on, an indirect control technique is designed and simulated. This control technique is achieved by phase shifting the input signal(voltage/current) by π/2.The overall action of the shunt active power filter to eliminat...

متن کامل

A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

In this paper, a refined reference current generation algorithm based on instantaneous power (pq) theory is proposed, for operation of an indirect current controlled (ICC) three-level neutral-point diode clamped (NPC) inverter-based shunt active power filter (SAPF) under non-sinusoidal source voltage conditions. SAPF is recognized as one of the most effective solutions to current harmonics due ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013