Validity and reproducibility of cephalometric measurements obtained from digital photographs of analogue headfilms.
نویسندگان
چکیده
UNLABELLED The emerging market of digital cephalographs and computerized cephalometry is overwhelming the need to examine the advantages and drawbacks of manual cephalometry, meanwhile, small offices continue to benefit from the economic efficacy and ease of use of analogue cephalograms. The use of modern cephalometric software requires import of digital cephalograms or digital capture of analogue data: scanning and digital photography. The validity of digital photographs of analogue headfilms rather than original headfilms in clinical practice has not been well established. Digital photography could be a fast and inexpensive method of digital capture of analogue cephalograms for use in digital cephalometry. AIM The objective of this study was to determine the validity and reproducibility of measurements obtained from digital photographs of analogue headfilms in lateral cephalometry. MATERIAL AND METHODS Analogue cephalometric radiographs were performed on 15 human dry skulls. Each of them was traced on acetate paper and photographed three times independently. Acetate tracings and digital photographs were digitized and analyzed in cephalometric software. Linear regression model, paired t-test intergroup analysis and coefficient of repeatability were used to assess validity and reproducibility for 63 angular, linear and derivative measurements. RESULTS AND CONCLUSIONS 54 out of 63 measurements were determined to have clinically acceptable reproducibility in the acetate tracing group as well as 46 out of 63 in the digital photography group. The worst reproducibility was determined for measurements dependent on landmarks of incisors and poorly defined outlines, majority of them being angular measurements. Validity was acceptable for all measurements, and although statistically significant differences between methods existed for as many as 15 parameters, they appeared to be clinically insignificant being smaller than 1 unit of measurement. Validity was acceptable for 59 of 63 measurements obtained from digital photographs, substantiating the use of digital photography for headfilm capture and computer-aided cephalometric analysis.
منابع مشابه
The reproducibility of cephalometric measurements: a comparison of analogue and digital methods.
The aim of this study was to compare the reproducibility of longitudinal cephalometric measurements between analogue and digital methods using two different resolutions. Cephalometric radiographs of 20 patients were selected at the start (T1) and end (T2) of treatment: 24 cephalometric variables were calculated at T1 and T2, and their increments (T2 - T1) were also evaluated. All measurements w...
متن کاملاعتبار و تکرارپذیری Dual Digital Inclinometer در اندازه گیری زاویه کایفوز پشتی در زنان بالای 45 سال
Objective: Accurate measurement of thoracic kyphosis has high value in the evaluation of patients with spinal kyphosis and in assessing the effectiveness of different treatment methods. Recently, Dual Digital Inclinometer (DDI) has introduced as a non-invasive tool that can measure the kyphosis angle. According to available information there is only one published study regarding the validity an...
متن کاملAccuracy and precision of measurements obtained from conventional cephalograms and CBCT scan in orthodontics linear diagnostic measurements
Background and Purpose: Due to the important role of imaging in the diagnosis and treatment plan in orthodontics, CBCT (Cone Beam Computed Tomography) images because of their three-dimensional nature, can minimize the disadvantages of two-dimensional images such as magnification, distortion, or superimposition. The purpose of this study was to evaluate the accuracy of conventional cephalograms...
متن کاملThe assessment of accuracy and reproducibility of cephalometric analyses using Computer- Assisted Simulation System for Orthognathic Surgery (CASSOS) software
Cephalometric analyses using computer software have more advantages than manual analyses. However, the software should be evaluated for the accuracy and reproducibility before it can be used. The aims of the present study were: 1) to compare the differences in accuracy and precision between utilizing scanned images and soft copy images with the software 2) to assess the reproducibility of softw...
متن کاملProfessionals' and laypersons' appreciation of various options for Class III surgical correction.
SUMMARY The objectives of this study were to evaluate the assessments of maxillofacial surgeons, orthodontists, and laypersons on the predicted aesthetic outcome of various surgical options in Class III correction and the associations between certain initial cephalometric values and the judges' preferred option. Pre-surgical lateral headfilms and coloured profile photographs of 18 skeletal Clas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stomatologija
دوره 9 4 شماره
صفحات -
تاریخ انتشار 2007