Construction of a Glucose Biosensor by Immobilizing Glucose Oxidase within a Poly(o- phenylenediamine) Covered Screen-printed Electrode
نویسنده
چکیده
The glucose biosensors were prepared by the electropolymerization of the non-conductive polymer, Poly(o-phenylenediamine), onto a planar screen-printed electrode. A fabrication procedure was performed to decrease the waste of expensive enzyme. The amperometric glucose response was measured by the potensiostating of the prepared glucose biosensors at a potential of 0.3 V with ferrocene as mediator. Results show that the obtained biosensors have a linear range up to 25 mM glucose, fast response time (100s) and high sensitivities (16.6 nA/mM). Also, the effects of applied potential and sweeping number of Cyclic voltammograms for electropolymerization were systematically investigated and optimal values were recorded.
منابع مشابه
Disposable electrochemiluminescent biosensor using bidentate-chelated CdTe quantum dots as emitters for sensitive detection of glucose.
A novel disposable solid-state electrochemiluminescent (ECL) biosensor was fabricated by immobilizing glucose oxidase and surface-unpassivated CdTe quantum dots (QDs) on a screen-printed carbon electrode (SPCE). The surface morphology of the biosensor was characterized with scanning electron microscopy and atomic force microscopy. With dissolved O(2) as an endogenous coreactant, QDs/SPCE showed...
متن کاملScreen-Printed Carbon Electrodes Modified by Rhodium Dioxide and Glucose Dehydrogenase
The described glucose biosensor is based on a screen-printed carbon electrode (SPCE) modified by rhodium dioxide, which functions as a mediator. The electrode is further modified by the enzyme glucose dehydrogenase, which is immobilized on the electrode's surface through electropolymerization with m-phenylenediamine. The enzyme biosensor was optimized and tested in model glucose samples. The bi...
متن کاملThe obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4
The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...
متن کاملThe obtain optimum production conditions for Glucose Oxidase biosensor using software Qualtek-4
The Glucose Oxidase (Gox) electrochemical sensors were used to detect a little amount of glucose. In this paper, the pure platinum plate (length of 5 cm and a width of 3 mm), the Ag/AgCl electrode and platinum electrode (diameter of 1 mm) were applied as a working electrode (W.E), reference electrode and auxiliary electrode sequential. Factors measured, glucose concentration and pH is Phosphate...
متن کاملCarbon nanotube composites for glucose biosensor incorporated with reverse iontophoresis function for noninvasive glucose monitoring
This study aims to develop an amperometric glucose biosensor, based on carbon nanotubes material for reverse iontophoresis, fabricated by immobilizing a mixture of glucose oxidase (GOD) and multiwalled carbon nanotubes (MWCNT) epoxy-composite, on a planar screen-printed carbon electrode. MWCNT was employed to ensure proper incorporation into the epoxy mixture and faster electron transfer betwee...
متن کامل