Beyond Affymetrix arrays: expanding the set of known hybridization isotherms and observing pre-wash signal intensities

نویسندگان

  • Alex E. Pozhitkov
  • Idrissa Boube
  • Marius H. Brouwer
  • Peter A. Noble
چکیده

Microarray hybridization studies have attributed the nonlinearity of hybridization isotherms to probe saturation and post-hybridization washing. Both processes are thought to distort 'true' target abundance because immobilized probes are saturated with excess target and stringent washing removes loosely bound targets. Yet the paucity of studies aimed at understanding hybridization and dissociation makes it difficult to align physicochemical theory to microarray results. To fill the void, we first examined hybridization isotherms generated on different microarray platforms using a ribosomal RNA target and then investigated hybridization signals at equilibrium and after stringent wash. Hybridization signal at equilibrium was achieved by treating the microarray with isopropanol, which prevents nucleic acids from dissolving into solution. Our results suggest that (i) the shape of hybridization isotherms varied by microarray platform with some being hyperbolic or linear, and others following a power-law; (ii) at equilibrium, fluorescent signal of different probes hybridized to the same target were not similar even with excess of target and (iii) the amount of target removed by stringent washing depended upon the hybridization time, the probe sequence and the presence/absence of nonspecific targets. Possible physicochemical interpretations of the results and future studies are discussed.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Explaining differences in saturation levels for Affymetrix GeneChip® arrays

The experimental spike-in studies of microarray hybridization conducted by Affymetrix demonstrate a nonlinear response of fluorescence intensity signal to target concentration. Several theoretical models have been put forward to explain these data. It was shown that the Langmuir adsorption isotherm recapitulates a general trend of signal response to concentration. However, this model fails to e...

متن کامل

A multi-array multi-SNP genotyping algorithm for Affymetrix SNP microarrays

MOTIVATION Modern strategies for mapping disease loci require efficient genotyping of a large number of known polymorphic sites in the genome. The sensitive and high-throughput nature of hybridization-based DNA microarray technology provides an ideal platform for such an application by interrogating up to hundreds of thousands of single nucleotide polymorphisms (SNPs) in a single assay. Similar...

متن کامل

Insight into the sequence specificity of a probe on an Affymetrix GeneChip by titration experiments using only one oligonucleotide

High-density oligonucleotide arrays are powerful tools for the analysis of genome-wide expression of genes and for genome-wide screens of genetic variation in living organisms. One of the critical problems in high-density oligonucleotide arrays is how to identify the actual amounts of a transcript due to noise and cross-hybridization involved in the observed signal intensities. Although mismatc...

متن کامل

Assessing Effect of Cross-hybridization on Oligonucleotide Microarrays

We introduce computational method, which allows estimating the input of non-specific binding into hybridization signal intensities on the oligonucleotide-based Affymetrix GeneChip arrays. We consider a simplified linear model of hybridization that should work well for microarray experiments with low DNA concentrations during hybridization, and use the quadratic programming technique to estimate...

متن کامل

Tips on hybridizing, washing, and scanning affymetrix microarrays.

Starting in the late 1990s, Affymetrix, Inc. produced a commercial system for hybridizing, washing, and scanning microarrays that was designed to be easy to operate and reproducible. The system used arrays packaged in a plastic cassette or chamber in which the prefabricated array was mounted and could be filled with fluid through resealable membrane ports either by hand or by an automated "flui...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 38  شماره 

صفحات  -

تاریخ انتشار 2010