Comparison of Neointimal Tissue Characteristics Between Bare-metal and Second-generation Drug-eluting Stents Nine Months after Implantation in Patients with ST-segment Elevation Myocardial Infarction
نویسندگان
چکیده
Background: Neointimal tissue characteristics after implantation of stents are related to late/ very late stent thrombosis and/ or restenosis of target lesion. However, the difference of them has not been fully elucidated among bare-metal stents (BMS) and second-generation drug-eluting stents (DES). Methods: The present study uses optical coherence tomography (OCT) to compare neointimal tissue characteristics among BMS (n = 22), Endeavor zotarolimus (E-ZES; n = 21), everolimus (EES; n = 22) and biolimus A9 (BES; n = 23) eluting stents in the patients with STEMI who underwent follow-up coronary angiography at nine months after stent implantation. Results: Quantitative coronary angiography revealed significantly higher restenosis rates for BMS and E-ZES than EES and BES. OCT showed significantly lower and higher rates for covered and uncovered EES, respectively, than for BMS and E-ZES. The malapposition rate for E-ZES was significantly lower than those of other two types of DES. The neointima of EES and BES was significantly thinner than that of BMS and E-ZES. Evagination was more prevalent in BES among the four stents, and the rate of evagination/strut significantly correlated with positive remodeling (r = 0.312, p = 0.006). Conclusion: Neointimal tissue characteristics were different among BMS and second-generation DES at nine months after implantation into patients with STEMI. This might be related to the differences of future cardiac events.
منابع مشابه
Sex-related Impact on Clinical Outcome of Everolimus-eluting Versus Bare-metal Stents in ST-segment Myocardial Infarction. Insights From the EXAMINATION Trial.
INTRODUCTION AND OBJECTIVES The use of second-generation drug-eluting stents compared with bare-metal stents in patients with ST-segment elevation myocardial infarction reduces the rate of major adverse cardiac events. We aimed to evaluate the impact of sex on the performance of everolimus-eluting stents vs bare-metal stents in ST-segment elevation myocardial infarction at 2-year follow-up. M...
متن کاملDrug-eluting versus bare metal stents in patients with st-segment-elevation myocardial infarction: eight-month follow-up in the Drug Elution and Distal Protection in Acute Myocardial Infarction (DEDICATION) trial.
BACKGROUND Implantation of drug-eluting stents (DES) limits the rate of coronary restenosis in most patients with coronary artery disease, but data are scarce with regard to their use in patients with ST-segment-elevation myocardial infarction and in connection with distal protection of the microvascular perfusion during primary percutaneous coronary intervention. METHODS AND RESULTS We rando...
متن کاملComparison of outcome in 1809 patients treated with drug-eluting stents or bare-metal stents in a real-world setting
PURPOSE The aim of this study was to determine the long-term safety of drug-eluting stent (DES) versus bare metal stent (BMS) implantation in a "real-world" setting. PATIENTS AND METHODS A total of 1809 patients who were treated with implantation of either BMS or DES were assessed. Kaplan-Meier and multivariate Cox regression analyses concerning primary endpoint of cardiac mortality were perf...
متن کاملPaclitaxel-eluting stents versus bare-metal stents in acute myocardial infarction.
BACKGROUND There is no consensus regarding the safety and efficacy of drug-eluting stents, as compared with bare-metal stents, in patients with ST-segment elevation myocardial infarction who are undergoing primary percutaneous coronary intervention (PCI). METHODS We randomly assigned, in a 3:1 ratio, 3006 patients presenting with ST-segment elevation myocardial infarction to receive paclitaxe...
متن کاملFive-Year Optical Coherence Tomography in Patients With ST-Segment-Elevation Myocardial Infarction Treated With Bare-Metal Versus Everolimus-Eluting Stents.
BACKGROUND The main causes of late (>1 month) stent thrombosis (ST) are stent uncoverage, malapposition, and neoatherosclerosis. First-generation drug-eluting stents were associated with higher rate of late ST compared with bare-metal stents (BMS), especially in patients with ST-segment-elevation myocardial infarction. Second-generation everolimus-eluting stents (EES) have shown similar rate of...
متن کامل