چکیده

OBJECTIVES The objective of this study was to compare the incidence of cerebral embolism (CE) as evaluated by diffusion-weighted magnetic resonance imaging (DW-MRI) following transapical (TA) transcatheter aortic valve implantation (TAVI) versus transfemoral (TF) TAVI. BACKGROUND The TA-TAVI approach avoids both the manipulation of large catheters in the aortic arch/ascending aorta and the retrograde crossing of the aortic valve, and this avoidance might lead to a lower rate of CE. METHODS This was a prospective multicenter study including 60 patients who underwent cerebral DW-MRI the day before and within the 6 days following TAVI (TF approach: 29 patients; TA approach: 31 patients). Neurologic and cognitive function assessments were performed at DW-MRI time points. RESULTS The TAVI procedure was performed with the Edwards valve and was successful in all cases but one (98%). A total of 41 patients (68%) had 251 new cerebral ischemic lesions at the DW-MRI performed 4 ± 1 days after the procedure, 19 patients in the TF group (66%) and 22 patients in the TA group (71%; p = 0.78). Most patients (76%) with new ischemic lesions had multiple lesions (median number of lesions per patient: 3, range 1 to 31). There were no differences in lesion number and size between the TF and TA groups. No baseline or procedural factors were found to be predictors of new ischemic lesions. The occurrence of CE was not associated with a measurable impairment in cognitive function, but 2 patients (3.3%) had a clinically apparent stroke within the 24 h following the procedure (1 patient in each group). CONCLUSIONS TAVI is associated with a high rate of silent cerebral ischemic lesions as evaluated by DW-MRI, with no differences between the TF and TA approaches. These results provide important novel insight into the mechanisms of CE associated with TAVI and support the need for further research to both reduce the incidence of CE during these procedures and better determine their clinical relevance.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Valvular Heart Disease Thirty-Day Results of the SAPIEN Aortic Bioprosthesis European Outcome (SOURCE) Registry A European Registry of Transcatheter Aortic Valve Implantation Using the Edwards SAPIEN Valve

Background—Transcatheter aortic valve implantation was developed to mitigate the mortality and morbidity associated with high-risk traditional aortic valve replacement. The Edwards SAPIEN valve was approved for transcatheter aortic valve implantation transfemoral delivery in the European Union in November 2007 and for transapical delivery in January 2008. Methods and Results—The SAPIEN Aortic B...

متن کامل

Transapical approach for transcatheter aortic valve implantation.

With the advancement of device technology and procedural techniques, most transcatheter aortic valve implantation (TAVI) procedures have been performed with the transfemoral approach in recent years (1). However, alternative approaches such as transapical, trans-subclavian, direct aortic and others still play an important role in patients with poor vascular access. Transapical approach is the o...

متن کامل

Transcatheter aortic valve implantation: is anatomy still the limiting factor?

INTRODUCTION Despite rapid advances in transcatheter aortic valve prostheses, anatomical constraints remain that can limit access to this treatment for patients with severe aortic stenosis. The objective of this study was to determine the proportion of patients anatomically suitable for this technique using the different devices and approaches available. METHODS We retrospectively analyzed 14...

متن کامل

Stroke Cerebral Embolization During Transcatheter Aortic Valve Implantation A Transcranial Doppler Study

Background—Transcatheter aortic valve implantation (TAVI) is associated with a higher risk of neurological events for both the transfemoral and transapical approach than surgical valve replacement. Cerebral magnetic resonance imaging has revealed more new, albeit clinically silent lesions from procedural embolization, yet the main source and predominant procedural step of emboli remain unclear....

متن کامل

Long-term results of transapical versus transfemoral TAVI in a real world population of 1000 patients with severe symptomatic aortic stenosis.

BACKGROUND Transapical transcatheter aortic valve implantation is generally perceived to be associated with increased morbidity compared with transfemoral transcatheter aortic valve implantation. We aimed to compare access-related complications and survival using propensity score matching. METHODS AND RESULTS Prospective, single-center registry of 1000 consecutive patients undergoing transapi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the American College of Cardiology

دوره 57 1  شماره 

صفحات  -

تاریخ انتشار 2011