Intra-operative defibrillation testing and clinical shock efficacy in patients with implantable cardioverter-defibrillators: the NORDIC ICD randomized clinical trial

نویسندگان

  • Dietmar Bänsch
  • Hendrik Bonnemeier
  • Johan Brandt
  • Frank Bode
  • Jesper Hastrup Svendsen
  • Miloš Táborský
  • Stefan Kuster
  • Carina Blomström-Lundqvist
  • Angelika Felk
  • Tino Hauser
  • Anna Suling
  • Karl Wegscheider
چکیده

AIMS This trial was designed to test the hypothesis that shock efficacy during follow-up is not impaired in patients implanted without defibrillation (DF) testing during first implantable cardioverter-defibrillator (ICD) implantation. METHODS AND RESULTS Between February 2011 and July 2013, 1077 patients were randomly assigned (1 : 1) to first time ICD implantation with (n = 540) or without (n = 537) DF testing. The intra-operative DF testing was standardized across all participating centres, and all ICD shocks were programmed to 40 J irrespective of DF test results. The primary end point was the average first shock efficacy (FSE) for all true ventricular tachycardia and fibrillation (VT/VF) episodes during follow-up. The secondary end points included procedural data, serious adverse events, and mortality. During a median follow-up of 22.8 months, the model-based FSE was found to be non-inferior in patients with an ICD implanted without a DF test, with a difference in FSE of 3.0% in favour of the no DF test [confidence interval (CI) -3.0 to 9.0%, Pnon-inferiority <0.001 for the pre-defined non-inferiority margin of -10%). A total of 112 procedure-related serious adverse events occurred within 30 days in 94 patients (17.6%) tested compared with 89 events in 74 patients (13.9%) not tested (P = 0.095). CONCLUSION Defibrillation efficacy during follow-up is not inferior in patients with a 40 J ICD implanted without DF testing. Defibrillation testing during first time ICD implantation should no longer be recommended for routine left-sided ICD implantation.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Defibrillation testing is not required during routine ICD implantation.

Sudden cardiac death (SCD) is a major cause of mortality throughout the world, accounting for 300 000 deaths per year in the USA. The introduction of the implantable cardioverter defibrillator (ICD) in the 1980s significantly reduced the risk of SCD by terminating life-threatening ventricular tachyarrhythmias. Subsequent clinical trials confirmed the survival benefit with implanted ICDs in at-r...

متن کامل

Effect of amiodarone and sotalol on ventricular defibrillation threshold: the optimal pharmacological therapy in cardioverter defibrillator patients (OPTIC) trial.

BACKGROUND Many patients with implanted cardioverter defibrillators (ICDs) receive adjunctive antiarrhythmic drug therapy, most commonly amiodarone or sotalol. The effects of these drugs on defibrillation energy requirements have not been previously assessed in a randomized controlled trial. METHODS AND RESULTS The Optimal Pharmacological Therapy in Cardioverter Defibrillator Patients (OPTIC)...

متن کامل

Inductionless or limited shock testing is possible in most patients with implantable cardioverter- defibrillators/cardiac resynchronization therapy defibrillators: results of the multicenter ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduction Evaluation With Implantable Cardioverter-Defibrillator Implantations).

BACKGROUND Implantable cardioverter-defibrillators and cardiac resynchronization therapy defibrillators have relied on multiple ventricular fibrillation (VF) induction/defibrillation tests at implantation to ensure that the device can reliably sense, detect, and convert VF. The ASSURE Study (Arrhythmia Single Shock Defibrillation Threshold Testing Versus Upper Limit of Vulnerability: Risk Reduc...

متن کامل

Intraoperative Defibrillation Testing of Subcutaneous Implantable Cardioverter‐Defibrillator Systems—A Simple Issue?

BACKGROUND The results of the recently published randomized SIMPLE trial question the role of routine intraoperative defibrillation testing. However, testing is still recommended during implantation of the entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) system. To address the question of whether defibrillation testing in S-ICD systems is still necessary, we analyzed the dat...

متن کامل

Subcutaneous Implantable Cardioverter Defibrillators Implantation Without Defibrillation Threshold Testing: A Single Center Experience

Background Subcutaneous implantable cardioverter defibrillator (S-ICD) system has been proven to be an effective therapy for prevention of sudden cardiac death (SCD) in selected patients. Although the Shockless IMPLant Evaluation (SIMPLE) trial has shown that defibrillation threshold (DFT) testing is not necessary for transvenous ICD (TV-ICD) systems, it is still recommended for S-ICD systems. ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 36  شماره 

صفحات  -

تاریخ انتشار 2015