Toxicity testing of 16 priority polycyclic aromatic hydrocarbons using Lumistox.
نویسندگان
چکیده
Hazard assessment of industrial sites contaminated with coal tar and its products usually focuses on selected pollutants such as the 16 polycyclic aromatic hydrocarbons (PAHs) prioritized by the U.S. Environmental Protection Agency (U.S. EPA). The aim of this study was to investigate to which extent these 16 PAHs contribute to the Vibrio fischeri bioluminescence inhibition measured by the acute Lumistox luminescent bacteria test. Five of the 16 PAHs-naphthalene (NAP), acenaphthylene (ACY), acenaphthene (ACE), fluorene (FLU), and phenanthrene (PHE)-revealed inhibiting effects when measuring saturated aqueous solutions of these compounds. However, in elutriates of PAH-contaminated soils, the amount of leached PAHs was very low, and the 16 PAHs did not considerably contribute to the observed bioluminescence inhibition. Nevertheless, bioluminescence inhibition was higher for elutriates with increased PAH concentration indicating the presence of other toxicants that co-occur with the 16 PAHs. No evidence was observed for increased bioluminescence inhibition due to synergistic effects among PAHs as calculated on the basis of toxic units for an aqueous solution containing all 16 priority PAHs. Data suggest that the U.S. EPA PAHs play only a minor role in causing acute toxicity to V. fischeri when exposed to aqueous elutriates of PAH-contaminated soils.
منابع مشابه
Determination of 16 priority polycyclic aromatic hyDrocarbons in bottom seDiments of the Danube estuarine coast by Gc/ms
16 priority polycyclic hydrocarbons were identified and determined quantitatively by gas chromatography-mass spectrometry method in bottom sediments of estuarine coast of Danube. Concentration of the sum of 16 polyarenes in bottom sediments ranged from 329.6 to 1093.3 μg/kg. The total B(a)Peqv, whose values at the stations of sampling ranged from 34.9 to 195.1 μg/kg, was determined to evaluate ...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملSimultaneous Determination of 13 Priority Polycyclic Aromatic Hydrocarbons in Tehran’s Tap Water and Water for Injection Samples Using Dispersive Liquid-Liquid Micro Extraction Method and Gas Chromatography-Mass Spectrometry
Abstract Polycyclic aromatic hydrocarbons (PAHs) are classified as persistent and carcinogenic organic pollutants. PAHs contamination has been reported in water. Many of relevant regulatory bodies such as EU and EPA have regulated the limit levels for PAHs in drinking water. In this study, 13 priority polycyclic aromatic hydrocarbons (PAHs) were determined in tap water samples of Tehran and wat...
متن کاملComparison of rapid solvent extraction systems for the GC–MS/MS characterization of polycyclic aromatic hydrocarbons in aged, contaminated soil
Polycyclic aromatic hydrocarbons (PAHs) are a major class of organic hydrocarbons with high molecular weight that originate from both natural and anthropogenic sources. Sixteen PAHs are included in the U.S Environmental Protection agency list of priority pollutants due to their mutagenic, carcinogenic, toxic and teratogenic properties. In this study, the development and optimization of a simpli...
متن کاملValidation of an Analytical Method for Determination of 13 priority polycyclic aromatic hydrocarbons in mineral water using dispersive liquid-liquid microextraction and GC-MS
Dispersive liquid liquid microextraction (DLLME) combined with gas chromatography–mass spectrometry (GC–MS) was used for the extraction and determination of 13 polycyclic aromatic hydrocarbons (PAHs) in mineral water samples. In this procedure, the suitable combination of extraction solvent (500 µL chloroform) and disperser solvent (1000 µL acetone) were quickly injected into the water sample (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Environmental toxicology and chemistry
دوره 23 3 شماره
صفحات -
تاریخ انتشار 2004