Airborne Electro-Mechanical Actuator Test Stand for Development of Prognostic Health Management Systems

نویسندگان

  • Edward Balaban
  • Abhinav Saxena
  • Sriram Narasimhan
  • Indranil Roychoudhury
  • Kai F. Goebel
  • Michael T. Koopmans
چکیده

With the advent of the next generation of aerospace systems equipped with fly-by-wire controls, electromechanical actuators (EMA) are quickly becoming components critical to safety of aerospace vehicles. Being relatively new to the field, however, EMA lack the knowledge base compared to what is accumulated for the more traditional actuator types, especially when it comes to fault detection and prognosis. Scarcity of health monitoring data from fielded systems and prohibitive costs of carrying out real flight tests create the need to build high-fidelity system models and design affordable yet realistic experimental setups. The objective of this work is to build an EMA test stand that, unlike current laboratory stands typically weighing in excess of one metric ton, is portable enough to be easily placed aboard a wide variety of aircraft. This stand, named the FLEA (for Flyable Electromechanical Actuator test stand), allows testing EMA fault detection and prognosis technologies in flight environment, thus substantially increasing their technology readiness level – all without the expense of dedicated flights, as the stand is designed to function as a non-intrusive secondary payload. No aircraft modifications are required and data can be collected during any available flight opportunity: pilot currency flights, ferry flights, or flights dedicated to other experiments. The stand is currently equipped with a prototype version of NASA Ames developed prognostic health management system with models aimed at detecting and tracking several fault types. At this point the team has completed test flights of the stand on US Air Force C-17 aircraft and US Army UH-60 helicopters and more experiments, both laboratory and airborne, are planned for the coming months.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Experimental Validation of a Prognostic Health Management System for Electro-Mechanical Actuators

Electro-Mechanical Actuators (EMA) are gaining prominent roles in the next generation fly-by-wire aircraft and spacecraft. With these roles often being safety-critical (control surface or landing gear actuation, for instance), the key to faster adoption of EMA in aerospace applications is development of accurate and reliable prognostic health management (PHM) systems that not only detect and id...

متن کامل

Fault Detection Based on Type 2 Fuzzy system for Single-Rod Electrohydraulic Actuator

Electro-hydraulic systems with regards to the their specific features and applications among other industrial systems including mechanical, electrical and pneumatic systems, have been widely taken into consideration by the scientists and researchers. Due to the fact that the electro-hydraulic system is inherently a nonlinear system, has some problems such as signals saturation, nonlinear effici...

متن کامل

Simulation of a Microgripper with Electrothermal Actuator Using COMSOL Software Based on the Finite Element Method

Micro-electro-mechanical systems (MEMs) are Combination of electrical and mechanical components in Micron dimensions. In recent years, holding, actuating methods and handling of MEMs components such as microgripper, microsensors and etc. have been deeply studied. Microgrippers for handling, positioning and assembling of micro components are very useful so that for clamping need actuation create...

متن کامل

Simulation of a Microgripper with Electrothermal Actuator Using COMSOL Software Based on the Finite Element Method

Micro-electro-mechanical systems (MEMs) are Combination of electrical and mechanical components in Micron dimensions. In recent years, holding, actuating methods and handling of MEMs components such as microgripper, microsensors and etc. have been deeply studied. Microgrippers for handling, positioning and assembling of micro components are very useful so that for clamping need actuation create...

متن کامل

Experimental Data Collection and Modeling for Nominal and Fault Conditions on Electro-Mechanical Actuators

Being relatively new to the field, electromechanical actuators in aerospace applications lack the knowledge base compared to ones accumulated for the other actuator types, especially when it comes to fault detection and characterization. Lack of health monitoring data from fielded systems and prohibitive costs of carrying out real flight tests push for the need of building system models and des...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010