A Surgical Cryoprobe for Targeted Transcorneal Freezing and Endothelial Cell Removal

نویسندگان

  • Alina Akhbanbetova
  • Shinichiro Nakano
  • Stacy L Littlechild
  • Robert D Young
  • Madara Zvirgzdina
  • Nigel J Fullwood
  • Ian Weston
  • Philip Weston
  • Shigeru Kinoshita
  • Naoki Okumura
  • Noriko Koizumi
  • Andrew J Quantock
چکیده

PURPOSE To examine the effects of transcorneal freezing using a new cryoprobe designed for corneal endothelial surgery. METHODS A freezing console employing nitrous oxide as a cryogen was used to cool a series of different cryoprobe tip designs made of silver for high thermal conductivity. In vitro studies were conducted on 426 porcine corneas, followed by preliminary in vivo investigations on three rabbit corneas. RESULTS The corneal epithelium was destroyed by transcorneal freezing, as expected; however, the epithelial basement membrane remained intact. Reproducible endothelial damage was optimally achieved using a 3.4 mm diameter cryoprobe with a concave tip profile. Stromal edema was seen in the pre-Descemet's area 24 hrs postfreeze injury, but this had been resolved by 10 days postfreeze. A normal collagen fibril structure was seen 1 month postfreeze, concurrent with endothelial cell repopulation. CONCLUSIONS Transcorneal freezing induces transient posterior stromal edema and some residual deep stromal haze but leaves the epithelial basement membrane intact, which is likely to be important for corneal re-epithelialization. Localized destruction of the endothelial monolayer was achieved in a consistent manner with a 3.4 mm diameter/concave profile cryoprobe and represents a potentially useful approach to remove dysfunctional corneal endothelial cells from corneas with endothelial dysfunction.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Corneal cell viability and structure after transcorneal freezing–thawing in the human cornea

PURPOSE Although cryotherapy has long been used to eradicate corneal lesions, there have been no reports of adverse effects of cryotherapy on human corneas. We performed this study to evaluate and characterize ultrastructural damage to the human cornea following the transcorneal freezing-and-thawing procedure. METHODS Seven human donor corneas were randomly divided into three groups. 1, 2, an...

متن کامل

A Surgical Cryoprobe for Targeted Transcorneal Freezing to Treat Corneal Endothelial Dysfunction

Program Number: 1248 Poster Board Number: D0196 Presentation Time: 3:15 PM–5:00 PM A Surgical Cryoprobe for Targeted Transcorneal Freezing to Treat Corneal Endothelial Dysfunction Alina Akhbanbetova1, Shinichiro Nakano2, Stacy L. Littlechild1, Robert D. Young1, Madara Zvirgzdina1, Nigel J. Fullwood3, Shigeru Kinoshita4, Naoki Okumura2, Noriko Koizumi2, Andrew J. Quantock1. 1Optometry and Vision...

متن کامل

Effects of transcorneal freezing on protein content of aqueous humor and intraocular temperature in rabbit and cat.

The effects of transcorneal freezing on protein content of aqueous humor and intraocular temperature at the posterior surface of the cornea, the angle, the iris, and the ciliary processes were determined in rabbits and cats. Normal aqueous protein concentration was 40 +/- 2 mg/dl in rabbits and 43 +/- 4 mg/dl in cats. In rabbits, total aqueous protein content reached its highest level (2790 +/-...

متن کامل

Suturing Technique to Promote Graft Attachment in Challenging Cases of Descemet Stripping Endothelial Keratoplasty

Aims: To describe a technique that uses a transcorneal fixation suture for graft attachment in endothelial keratoplasty in high-risk for graft dislocation eyes. Materials and Methods: Case series included 12 eyes of 12 patients who underwent Descemet Stripping Automated Endothelial Keratoplasty (DSAEK) in the presence of high risk for graft dislocation factors. We describe a surgical technique ...

متن کامل

Correlation of corneal endothelial pump site density, barrier function, and morphology in wound repair.

After transcorneal freezing, physiologic function (pump and barrier) of the regenerating rabbit corneal endothelium was evaluated and compared with the morphologic differentiation that occurs during wound healing. Endothelial pump function was investigated utilizing the specific binding of tritiated ouabain to endothelial Na+/K+ ATPase (pump sites); the permeabilities of isolated de-epitheliali...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2017  شماره 

صفحات  -

تاریخ انتشار 2017