The determination of erythrocyte folate concentration using a two-phase ligand-binding radioassay.

نویسندگان

  • S P Rothenberg
  • M da Costa
  • J Lawson
  • Z Rosenberg
چکیده

The concentration of folate in erythrocytes was determined using a two-phase ligandbIndIng radloasuy procedure described previously for measuring serum folate. The mean (± SD) folate concentration In erythrocytes of 20 normal subjects was 210 * 67 ng/mI. In 12 patients clinically folate deficient who had normal serum B2 concentration, the mean (± SD) erythrocyte folate was 71 * 39 ng/ml. Incubation of the lysed erythrocytes for 2 hr prior to boiling increased the radioassayable folate. The radloassayable folate decreased rapidly If the whole blood was stored at 4#{176}C without ascorbate. Extracts of blood prepared with ascorbate could be stored at -20#{176} C for several days. The radloassayable concentration of erythrocyte folate was similar to the values obtained using Lactobacillus case! when the concentration was 200 ng/ ml or less. With values higher by L. case!, the radioassayable folate was significantly lower even though the normal and folatedeficient groups were distinctly separated. This radioassay provides a rapid and reliable method of measuring erythrocyte folate, a parameter which reflects folate stores more reliably than serum folate concentration.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Determination of Erythrocyte Folate Concentration Using a Two - Phase Ligand - binding

The concentration of folate in erythrocytes was determined using a two-phase ligandbIndIng radloasuy procedure described previously for measuring serum folate. The mean (± SD) folate concentration In erythrocytes of 20 normal subjects was 210 * 67 ng/mI. In 12 patients clinically folate deficient who had normal serum B2 concentration, the mean (± SD) erythrocyte folate was 71 * 39 ng/ml. Incuba...

متن کامل

Radiochemical method for measuring plasma clearance and urinary excretion of pteroylglutamic acid.

A radiochemical procedure is described for specific determination of pteroylglutamate in serum and urine. This method depends on denaturation of methyltetrahydrofolate with peroxide and measurement of the residual folate by a ligand-binding radioassay. The binding determinant for the radioassay is a folate-binding protein, partially purified from chronic myelogenous lekemia cells, that has low ...

متن کامل

Analytical evaluation of a folate radioassay: application to serum and erythrocyte measurements.

Many commercial folate radioassay kits have proven to be unsatisfactory in the past. It has been found that the Schwarz/Mann Iodine-125 folate radioassay kit permits a rapid measurement of folic acid requiring only a single incubation at pH 9.3. At this pH, the relative affinity of pteroylglutamic acid (FA) and N-5-methyltetrahydrofolic acid (MTFA) for the milk binder is the same. Additionally,...

متن کامل

Two radioassays for serum vitamin B12 and folate determination compared in a reference interval study.

For 154 subjects, we verified that vitamin B12 and folate status was normal, using as criteria the average polymorphonuclear lobe count, mean corpuscular volume, and hemoglobin concentration. We then used blood from these subjects to compare values obtained with two radioassay kits, each designed for simultaneous vitamin B12 and folate determination. Although regression analysis showed reasonab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Blood

دوره 43 3  شماره 

صفحات  -

تاریخ انتشار 1974