Structure and operation of skeletal apparatus of authors own design for the repair of zygomatico-orbital fractures
نویسندگان
چکیده
Zygomatico-orbital fractures are a frequent sequel to trauma of the facial skeleton. The treatment of these fractures is various, depending on their clinical and radiological pictures. The authors describe these methods of positioning and immobilization of zygomatico-orbital fractures that have been used for years. In this context, the Jankowski’s frame and its subsequent modifications should be mentioned. The paper presents the project and operation patterns of a framework device being designed by authors and used in reposition and fixation of zygomatico-orbital fractures. This device was successfully used in the treatment of 70 patients.
منابع مشابه
Management of Zygomatico-orbital Fractures Using Rigid Internal Fixation with Cosmetic Surgical Considerations - Case Report
The current standard of managing facial bone fractures is the use of rigid internal fixation. This method provides good stabilization and repair for mid-face fractures such as the zygomatico-orbital fracture. Nowadays, for the young and old, patients want not only rapid bone healing, but also good facial aesthetics after surgical treatment following maxillofacial trauma. Therefore, osteosynthes...
متن کاملISOLATED Z YGOMATICO-ORBI TAL INJURIES (lZOIs) IN TEHRAN: AN ANALYSIS OF 375 C ASES
Zygomatico-orbital injuries (ZOls) are the most common injuries treated by the oral and maxillofacial surgeons. A respective analysis of 375 pateints with 1Z0ls treated in Najmeia and Baqiet-Ullah University Hospitals during a six-year period from 1984 to 1990 is presented. Male cases accounted for 94.4% (354) 59.46% (223) of the fractures involved the zygomatic bone, 70.13% (259) were frac...
متن کاملThe Merits of Mannitol in the Repair of Orbital Blowout Fracture
BACKGROUND One of the main concerns in orbital blowout fracture repair is a narrow operation field, due mainly to the innate complex three dimensions of the orbit; however, a deep location and extensive area of the fracture and soft tissue edema can also cause concern. Swelling of the orbital contents progresses as the operation continues. Mannitol has been used empirically in glaucoma, cerebra...
متن کاملبررسی ده ساله شکستگیهای اوربیت در یک مرکز آموزشی
Normal 0 false false false EN-GB X-NONE AR-SA MicrosoftInternetExplorer4 !mso]> st1":*{behavior:url(#ieooui) } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal" mso-tst...
متن کاملComparison of close reduction and percutaneous pin fixation as treatments for distal metaphyseal radius fractures
Background: Distal radius fractures are one of the most common fractures of skeletal system and because of the aging of population, its incidence is rising. The aim of the present research was to evaluate the close reduction and percutaneous pin fixation as a treatment option. Material and methods: 44 patients who were type 2 according to universal classification or type 2 or 3 according to Ol...
متن کامل