Index Terms—Shunt Active Filter, Fuzzy Logics, FFT analysis, Harmonic Distortion I. POWER QUALITY IN POWER SYSTEMS

نویسندگان

  • Kamalesh sharma
  • Sunil kumar goyal
  • Nagendra kumar swarnkar
چکیده

9 www.alliedjournals.com  Abstract— Power quality is a very important issue. Non-linear loads and semi-conductor devices connected to AC electric mains generate unwanted signals (harmonics) in the dynamics of current which are responsible for additional power losses in heat loss and the risk of equipment damage or malfunctioning. In the simulink model of shunt active filter fuzzy logic controller and hysteresis current controller for reducing the harmonic distortion. Powergui tool of mat lab provides the function of FFT analysis which is very important to calculate total harmonic distortion in source current. By taking various firing angles the total harmonic distortion is calculated by FFT analysis.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Pi, Fuzzy Logic Controlled Shunt Active Power Filter for Three-phase Four-wire Systems with Balanced, Unbalanced and Variable Loads

This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Variable load condi...

متن کامل

A Novel Approach for Enhancement of Power Quality by Reduction of Total Harmonic Disortion in Three Phase Four Wire System

This paper presents a fuzzy logic, PI, average current controlled shunt active power filter used to compensate for harmonic distortion in three-phase four-wire systems. The shunt active filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Shunt Active Power filter is able to operate in balanced, unbalanced and Va...

متن کامل

Robust Control of Shunt Active Power Filter Using Interval Type-2 Fuzzy Logic Controller for Power Quality Improvement

Original scientific paper It is well-known that shunt active power filter (SAPF) is widely used to reduce harmonic distortion and to compensate reactive power in electrical power systems. DC bus voltage control of SAPF is very important for excellent power quality. In the control of SAPF, DC bus voltage is controlled by conventional control methods such as PI and PID controllers. However, these...

متن کامل

Fuzzy Logic Controller Based Three-phase Shunt Active Filter for Line Harmonics Reduction

Harmonic distortion is a form of electrical noise. It is a superposition of signals, which are of multiples of fundamental frequency. Proliferation of large power electronic systems results in increased harmonic distortion. Harmonic distortion results in reduction of power quality and system stability. This paper presents fuzzy control applicable for active power filter for three-phase systems,...

متن کامل

A Comparative Analysis of PI Controller and Fuzzy Logic Controller for Hybrid Active Power Filter Using Dual Instantaneous Power Theory

This paper presents a fuzzy logic, PI controlled shunt active power filter used to compensate for harmonic distortion in three-phase systems. The Hybrid active power filter employs a simple method for the calculation of the reference compensation current based on Fast Fourier Transform. The presented Hybrid Active Power filter is able to operate in balanced, load conditions. Classic filters may...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015