Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images*

نویسندگان

  • Viriato Leal Neto
  • José Wilson Vieira
  • Fernando Roberto de Andrade Lima
چکیده

OBJECTIVE This article presents a way to obtain estimates of dose in patients submitted to radiotherapy with basis on the analysis of regions of interest on nuclear medicine images. MATERIALS AND METHODS A software called DoRadIo (Dosimetria das Radiações Ionizantes [Ionizing Radiation Dosimetry]) was developed to receive information about source organs and target organs, generating graphical and numerical results. The nuclear medicine images utilized in the present study were obtained from catalogs provided by medical physicists. The simulations were performed with computational exposure models consisting of voxel phantoms coupled with the Monte Carlo EGSnrc code. The software was developed with the Microsoft Visual Studio 2010 Service Pack and the project template Windows Presentation Foundation for C# programming language. RESULTS With the mentioned tools, the authors obtained the file for optimization of Monte Carlo simulations using the EGSnrc; organization and compaction of dosimetry results with all radioactive sources; selection of regions of interest; evaluation of grayscale intensity in regions of interest; the file of weighted sources; and, finally, all the charts and numerical results. CONCLUSION The user interface may be adapted for use in clinical nuclear medicine as a computer-aided tool to estimate the administered activity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Aplicativo para dosimetria interna usando a distribuição biocinética de fótons baseada em imagens de medicina nuclear* Application for internal dosimetry using biokinetic distribution of photons based on nuclear medicine images

Objetivo: Este artigo apresenta uma forma de se obterem estimativas de dose em pacientes submetidos a tratamentos radioterápicos a partir da análise das regiões de interesse em imagens de medicina nuclear. Materiais e Métodos: Foi desenvolvido o software denominado DoRadIo (Dosimetria das Radiações Ionizantes), que recebe as informações sobre os órgãos fontes e o órgão alvo e retorna resultados...

متن کامل

Development of a 9-months pregnant hybrid phantom and its internal dosimetry for thyroid agents

As a consequence of fetal radiosensitivity, the estimation of internal dose received by a fetus from radiopharmaceuticals applied to the mother is often important in nuclear medicine. A new 9-months pregnant phantom based on magnetic resonance (MR) images tied to the International Commission on Radiological Protection (ICRP) reference voxel phantom has been developed. Maternal and fetal organs ...

متن کامل

Internal dosimetry of radioiodine using ICRP reference phantoms and updated biokinetic model

The purpose of this study is to estimate internal dose to human body due to administration of I-131 using new biokinetic model of iodine. In this respect, we used international commission on radiological protection (ICRP) adult reference phantoms. Monte Carlo calculations were performed using MCNPX 2.6 code. The average dose to target organ per disintegration inside source organ, namely S facto...

متن کامل

Uncertainty and sensitivity analysis of biokinetic models for radiopharmaceuticals used in nuclear medicine.

Mathematical models for kinetics of radiopharmaceuticals in humans were developed and are used to estimate the radiation absorbed dose for patients in nuclear medicine by the International Commission on Radiological Protection and the Medical Internal Radiation Dose (MIRD) Committee. However, due to the fact that the residence times used were derived from different subjects, partially even with...

متن کامل

Image-based versus atlas-based patient-specific S-value assessment for Samarium-153 EDTMP cancer palliative care: A short study

Introduction: Use of SPECT/CT data is the most accurate method for patient-specific internal dosimetry when isotopes emit single gamma rays. The manual or semi-automatic segmentation of organs is a major obstacle that slows down and limits the patient-specific dosimetry. Using digital phantoms that mimic patient’s anatomy can bypass the segmentation step and facilitate the dosi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 47  شماره 

صفحات  -

تاریخ انتشار 2014