Mammographic Density Estimation with Automated Volumetric Breast Density Measurement

نویسندگان

  • Su Yeon Ko
  • Eun-Kyung Kim
  • Min Jung Kim
  • Hee Jung Moon
چکیده

OBJECTIVE To compare automated volumetric breast density measurement (VBDM) with radiologists' evaluations based on the Breast Imaging Reporting and Data System (BI-RADS), and to identify the factors associated with technical failure of VBDM. MATERIALS AND METHODS In this study, 1129 women aged 19-82 years who underwent mammography from December 2011 to January 2012 were included. Breast density evaluations by radiologists based on BI-RADS and by VBDM (Volpara Version 1.5.1) were compared. The agreement in interpreting breast density between radiologists and VBDM was determined based on four density grades (D1, D2, D3, and D4) and a binary classification of fatty (D1-2) vs. dense (D3-4) breast using kappa statistics. The association between technical failure of VBDM and patient age, total breast volume, fibroglandular tissue volume, history of partial mastectomy, the frequency of mass > 3 cm, and breast density was analyzed. RESULTS The agreement between breast density evaluations by radiologists and VBDM was fair (k value = 0.26) when the four density grades (D1/D2/D3/D4) were used and moderate (k value = 0.47) for the binary classification (D1-2/D3-4). Twenty-seven women (2.4%) showed failure of VBDM. Small total breast volume, history of partial mastectomy, and high breast density were significantly associated with technical failure of VBDM (p = 0.001 to 0.015). CONCLUSION There is fair or moderate agreement in breast density evaluation between radiologists and VBDM. Technical failure of VBDM may be related to small total breast volume, a history of partial mastectomy, and high breast density.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Area and Volumetric Density Estimation in Processed Full-Field Digital Mammograms for Risk Assessment of Breast Cancer

INTRODUCTION Mammographic density, the white radiolucent part of a mammogram, is a marker of breast cancer risk and mammographic sensitivity. There are several means of measuring mammographic density, among which are area-based and volumetric-based approaches. Current volumetric methods use only unprocessed, raw mammograms, which is a problematic restriction since such raw mammograms are normal...

متن کامل

Dependence of Radiation Dose on Area and Volumetric Mammographic Breast Density Estimation

Mammographic breast density is a strong risk factor for breast cancer. Studies on imaging dose in mammography have primarily focused on imaging quality and diagnostic accuracy, while little work has been done on understanding its effect on the estimation of breast density. Studies on the effect of dose on mammographic density estimation can be useful in dose reduction for the purpose of density...

متن کامل

Agreement of Mammographic Measures of Volumetric Breast Density to MRI

BACKGROUND Clinical scores of mammographic breast density are highly subjective. Automated technologies for mammography exist to quantify breast density objectively, but the technique that most accurately measures the quantity of breast fibroglandular tissue is not known. PURPOSE To compare the agreement of three automated mammographic techniques for measuring volumetric breast density with a...

متن کامل

Automated measurement of volumetric mammographic density: a tool for widespread breast cancer risk assessment.

INTRODUCTION Mammographic density is a strong risk factor for breast cancer and an important determinant of screening sensitivity, but its clinical utility is hampered due to the lack of objective and automated measures. We evaluated the performance of a fully automated volumetric method (Volpara). METHODS A prospective cohort study included 41,102 women attending mammography screening, of wh...

متن کامل

Association between 25-Hydroxy Vitamin D and volumetric breast density via a fully automated software Volpara™ in the reproductive age group

OBJECTIVE To determine the association between serum 25 hydroxyvitamin D levels and percent breast density among asymptomatic premenopausal women. METHODS Hundred asymptomatic, pre-menopausal women who visited the General Surgery Breast Clinic, Patel Hospital, Karachi, Pakistan between 3rd March and 10th November, 2015 were included in this study. The serum 25 (OH)D and calcium levels were me...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2014