Self-expanding nitinol stents in canine vertebral arteries: hemodynamics and tissue response.
نویسندگان
چکیده
PURPOSE To evaluate the hemodynamics and tissue response associated with stent placement in low-flow-velocity arteries. METHODS Six self-expanding nitinol stents (5.5 mm caliber) were implanted transfemorally within the proximal segments of vertebral arteries (2.5 mm diameter) in six adult dogs during anticoagulative protection. RESULTS Control angiograms demonstrated patency and 20% dilatation of all stented arteries. One artery was partially thrombosed 1 week later and subsequently showed a 50% stenosis. Throughout the observation period (4 to 9 months after stenting), the other five arteries remained patent without significant narrowing (< or = 15%). Small cervical muscle branches originating from the vertebral arteries within the stented segments remained patent. No major branch occlusions of the vertebrobasilar system were detected. Stent migration or kinking did not occur. MR studies of the brain 4 months after implantation revealed no infarcted areas. These findings were confirmed with brain sections. Stented artery specimens showed delayed stent dilatation. A comparison of the total mean thickness of intima covering the five 30- to 40-mm stents removed at 4, 6, and 9 months showed no significant difference (338, 332, and 389 microns, respectively). Histologic findings verified the macroscopic impression of a thicker intima at the inner curve of the stented artery segments and at the junctions of the stent filaments. The shortest (10 mm) stent had the thinnest neointimal growth (155 microns). Stented vessels showed compression of the media with atrophy, but without necrosis or perforation. Scanning electron photomicrographs revealed intact endothelial cell linings with typical elongated cells. CONCLUSIONS No significant risk of thromboembolic events exists after implanting these nitinol stents in nonatherosclerotic vertebral arteries in dogs. Thicker neointimal growth after stenting may result from either low wall shear stress with possible flow separation or from changes in the shape and size of the stent, or both.
منابع مشابه
Oversizing of self-expanding stents: influence on the development of neointimal hyperplasia of the carotid artery in a canine model.
BACKGROUND AND PURPOSE In carotid artery stent placement, marked oversizing of the stent relative to the internal carotid artery lumen is common. This study was performed to determine the influence of using oversized self-expanding nitinol stents on neointimal hyperplasia. METHODS In six greyhound dogs, 24 self-expanding nitinol stents (eight SMART stents, eight Easy Wallstents, eight Sinus-F...
متن کاملSelf-expanding and balloon-expandable stents in the treatment of carotid aneurysms: an experimental study in a canine model.
PURPOSE To assess the efficacy of metal stents for the treatment of different forms and sizes of carotid aneurysms. METHODS A total of 14 experimentally constructed aneurysms in dogs were treated with transfemorally placed balloon-expandable tantalum and self-expanding nitinol stents. RESULTS In 10 cases, stenting produced either immediate complete occlusion of the aneurysm (n = 7) or compl...
متن کاملPrevention of carotid artery restenosis after sirolimus-coated stent implantation in pigs.
BACKGROUND AND PURPOSE To test the feasibility of self-expanding drug-coated nitinol stents for prevention of restenosis in an animal model. Stent implantation in the carotid artery (CA) has been shown to be feasible for treatment of CA stenosis. Even though the restenosis rate in CA is reported to be lower than in the coronary and peripheral arteries, problems may arise with increasing numbers...
متن کاملSelf-expanding versus balloon-mounted stents for vessel recanalization following embolic occlusion in the canine model: technical feasibility study.
BACKGROUND AND PURPOSE Despite advances in mechanical thrombolysis for acute stroke, recanalization rates remain approximately 50%-60%. Technologic improvements allowed safe intracranial delivery of stents. To study the feasibility of stent-assisted recanalization for acute stroke, we deployed self-expanding or balloon-mounted stents in 2- to 3.5-mm canine vessels acutely occluded with clot emb...
متن کاملConformity of carotid stents with vascular anatomy: evaluation in carotid models.
BACKGROUND AND PURPOSE Conformity between self-expanding Wallstents and vascular anatomy is limited. Because of a lack of longitudinal flexibility, straightening effects on vascular curves occur and may result in stent-induced kinking. Our purpose was to evaluate the conformity of self-expanding stents with the course and endoluminal surface of silicone models of the normal human carotid artery...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 16 5 شماره
صفحات -
تاریخ انتشار 1995