Xvi. Neurophysiology
نویسندگان
چکیده
At the time of the Quarterly Progress Report of April 15, 1958, I thought that no circuit could preserve error-free action if it were composed of 3 neurons, each receiving only 2 inputs. To correct this, let me replace the jot in any Venn symbol (1) by 1 if the jot is always present, by 0 if it is always absent, and by p if it is present with a probability p due to a shift of the threshold 0 of the neuron that it represents.
منابع مشابه
ALKALOIDS OF PAPAVERACEAE (XVI) [I]. ALKALOIDS OF PAPAVER FUGAX POPULATION TAROM
Papaverfugax Poiret population Tarom was shown to contain one major alkaloid, mecamberine (0.4%), and six minor alkaloids, roemerine, pronuciferine, protopine, thebaine, nornuciferine and salutaridine. Nornuciferine was detected for the first time in P. fugax
متن کاملNew classes of public key cryptosystem K(XVI)SE(1)PKC constructed based on Reed-Solomon code over extension field of m=8 and K(XVI)SE(2)PKC, based on binary cyclic code
In this paper, we first present a new class of code based public key cryptosystem(PKC) based on ReedSolomon code over extension field of less than m=9, referred to as K(XVI)SE(1)PKC. We then present a new class of quadratic multivariate PKC, K(XVI)SE(2)PKC, based on binary cyclic code. We show that both K(XVI)SE(1)PKC and K(XVI)SE(2)PKC can be secure against the various linear transformation at...
متن کاملInhibition of collagen XVI expression reduces glioma cell invasiveness.
Glioblastomas are characterized by an intense local invasiveness that limits surgical resection. One mechanism by which glioma cells enforce their migration into brain tissue is reorganization of tumour associated extracellular matrix (ECM). Collagen XVI is a minor component of connective tissues. However, in glioblastoma tissue it is dramatically upregulated compared to the ECM of normal corte...
متن کاملAn image quality comparison study between XVI and OBI CBCT systems
The purpose of this study is to evaluate and compare image quality characteristics for two commonly used and commercially available CBCT systems: the X-ray Volumetric Imager and the On-Board Imager. A commonly used CATPHAN image quality phantom was used to measure various image quality parameters, namely, pixel value stability and accuracy, noise, contrast to noise ratio (CNR), high-contrast re...
متن کاملAutomatic image registration performance for two different CBCT systems; variation with imaging dose
The performance of an automatic image registration algorithm was compared on image sets collected with two commercial CBCT systems, and the relationship with imaging dose was explored. CBCT images of a CIRS Virtually Human Male Pelvis phantom (VHMP) were collected on Varian TrueBeam/OBI and Elekta Synergy/XVI linear accelerators, across a range of mAs settings. Each CBCT image was registered 10...
متن کامل