Preconcentration of Cr(III), Co(II), Cu(II), Fe(III) and Pb(II) as calmagite chelates on cellulose nitrate membrane filter prior to their flame atomic absorption spectrometric determinations.

نویسندگان

  • M Soylak
  • U Divrikli
  • L Elci
  • M Dogan
چکیده

A method for the preconcentration and determination of Cr(III), Co(II), Cu(II), Fe(III) and Pb(II) ions by atomic absorption spectrometry has been described. The method was based the collection of metal-calmagite complexes on a soluble cellulose nitrate membrane filter. The detection of the solution was obtained by flame atomic absorption spectrometry (FAAS) after completely dissolving the membrane with 0.5 ml of nitric acid at 80 degrees C. The metal ions were recovered quantitatively at pH 8. Various factors which affect the collection and determination of metal ions such as, type and size of the membrane filter, solvent for dissolution of the species retained on the filter were investigated. The detection limits were varying 0.06 mug l(-1) for Cu to 2.5 mug l(-1) for Cr. An application of the proposed method for analyte ions in mineral and tap water samples was also described with satisfactory results (recoveries >95%, relative standard deviations <10%).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Metal Ion Uptake Behaviour of Nafion in Presence of Organic Complexing Reagents

Membrane separation is a very well known technology having a large number of applications. Separation of metal ions by selective membrane transport is of great importance from both fundamental and practical viewpoints. According to IUPAC, a membrane is defined as a heterogeneous phase which acts as a barrier to the flow of molecules and ionic species in liquid or vapour phase. Membranes can be ...

متن کامل

1,8-Dihydroxyanthraquinone anchored on silica gel: synthesis and application as solid phase extractant for lead(II), zinc(II) and cadmium(II) prior to their determination by flame atomic absorption spectrometry.

A new chelating matrix has been prepared by immobilizing 1,8-dihydroxyanthraquinone (DHAQ) on silica gel modified with (3-aminopropyl)triethoxysilane. After characterizing the matrix with thermogravimetric analysis (TGA), cross polarization magic angle spinning (CPMAS) NMR and diffuse reflectance infrared fourier transformation (DRIFT) spectroscopy, it has been used to preconcentrate Pb(II), Cd...

متن کامل

Extraction, preconcentration and spectrometric determination of Al (III) and Cr (III) ions using modified MnFe2O4 nanoparticles as an efficient adsorbent

An efficient and reusable adsorbent, namely 3-mercaptopropionic acid modified tetraethyl orthosilicate (TEOS) grafted MnFe2O4 nanoparticles (MPA-TEOS-MnFe2O4 NPs) was synthesized and used for the extraction and preconcentration of trace amount of Al (III) and Cr (III) ions in water samples. MnFe2O4 NPs were prepared by chemical c...

متن کامل

Silica gel functionalized with resacetophenone: synthesis of a new chelating matrix and its application as metal ion collector for their flame atomic absorption spectrometric determination

Silica gel modified with 3-aminopropyltriethoxysilane was anchored with resacetophenone to prepare a new chelating surface (or matrix). It was characterized with cross polarization magic angle spinning C NMR spectroscopy and diffuse reflectance infrared Fourier transform (DRIFT) spectroscopy and used for the separation and preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II), Zn(II) and ...

متن کامل

8-Hydroxyquinoline anchored to silica gel via new moderate size linker: synthesis and applications as a metal ion collector for their flame atomic absorption spectrometric determination.

The silica gel modified with (3-aminopropyl-triethoxysilane) was reacted with 5-formyl-8-hydroxyquinoline (FHOQ(x)) to anchor 8-quinolinol ligand on the silica gel. It was characterised with cross polarisation magic angle spinning (CPMAS) NMR and diffuse reflectance infrared Fourier transformation (DRIFT) spectroscopy and used for the preconcentration of Cu(II), Pb(II), Ni(II), Fe(III), Cd(II),...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Talanta

دوره 56 3  شماره 

صفحات  -

تاریخ انتشار 2002