Cardiac Cine Imaging in a single Breathhold using Elliptically reordered 3D TrueFISP

نویسنده

  • Klaus SCHEFFLER
چکیده

Introduction The TrueFISP sequence as proposed by Oppelt et. al. in 1986 (1) offers a high contrast between myocardium and intraventricular cavity, which is desirable for accurate assessment of ventricular function. A significant drawback of TrueFISP is its sensitivity to offresonance effects caused by an imperfect shim, chemical shifts, eddy currents, and Maxwell effects. An extension of the 2D TrueFISP sequence to an ecg-gated 3D TrueFISP sequence is thus not straight forward and requires a very carefully designed acquisition scheme. The current implementation of our gated 3D TrueFISP sequence allows to acquire the complete heart in its diastolic phase within about 20 heartbeats with a resolution of 2 x 2 x 3 mm. In addition, a 3D TrueFISP cine technique with a time resolution of 50 to 90 ms and a spatial resolution of 3 x 4 x 4 mm was implemented. Methods Besides offresonance effects generated by different susceptibilities and chemical shifts, eddy currents are a further source of signal insabilities for the TrueFISP sequence. Linear phase encoding as used for 2D TrueFISP sequences generates a smooth variation of the phase gradient amplitudes, and the nearly balanced amplitudes of the phase encoding gradients before and after the RF pulse act as an intrinsic eddy current compensation. In conventional 3D sampling patterns, however, 3D k-space is scanned line by line for each linearly increasing partition step. As a result, after each completed line scan, the line position is rewinded from the outermost position to the starting position while increasing one step in partition direction. At this point the intrinsic eddy current compensation fails since here the line phase encoding gradients have same amplitudes before (rewinder) and after (prewinder) the RF pulse. An alternating or zigzag sampling trajectory through lines and partitions as shown in Fig. 1 is proposed that eliminates this effect. This sampling pattern provides a smooth and small variation of the kspace encoding position between any successiv step of the encoding procedure.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doubled Scan Efficiency in Multi-slice Real-time Cine TrueFISP Cardiac Imaging by Pseudo-Continuous Sliding Slice Acquisition

Introduction: Real-time TrueFisp cardiac imaging allows multiple slice cine acquisitions within a single breathhold. Typically, the steady state preparation is established utilizing a full heartbeat per slice. Hence, only every other heartbeat is used to collect data. A simple elimination of the preparation heartbeats to increase scan efficiency compromises the contrast between blood and myocar...

متن کامل

Accelerating cardiac cine 3D imaging using k-t BLAST.

By exploiting spatiotemporal correlations in cardiac acquisitions using k-t BLAST, gated cine 3D acquisitions of the heart were accelerated by a net factor of 4.3, making single breathhold acquisitions possible. Sparse sampling of k-t space along a sheared grid pattern was implemented into a cine 3D SSFP sequence. The acquisition of low-resolution training data, which was required to resolve al...

متن کامل

Single breathhold three-dimensional cardiac cine MRI with whole ventricular coverage and retrospective cardiac gating using kat ARC

Background For quantitative volumetric assessments of cardiac function, 3D cine images depicting motion of the entire ventricle in a complete cardiac cycle are needed. However, due to limited acceleration capability, breathheld 3D cine MRI is not obtainable using conventional parallel imaging. Several kt-acceleration methods have demonstrated high-acceleration capability for dynamic MRI by expl...

متن کامل

Single-Breathhold Four-Dimensional Assessment of Left Ventricular Morphological and Functional Parameters by Magnetic Resonance Imaging Using the VAST Technique

INTRODUCTION The accurate and reproducible assessment of cardiac volumes, function, and mass is of paramount importance in cardiology. In the present study we sought to determine whether the 3D cine-magnetic resonance (MR) technique, using the variable asymmetric sampling in time (VAST) approach, provided an accurate assessment of LV functional parameters when compared with the conventional 2D ...

متن کامل

Robust Free-Breathing Whole-Heart Cine MRI using Multi-Slab 3D Acquisition with Isotropic Resolution and Offline Reformattability

Purpose: Cardiac cine MRI has become a routine exam for assessment of cardiac function and anatomy. Conventional 2D cine requires separate scouting scans to localize different views and at each orientation multiple breathholds are required with patient recuperation time in-between breathholds. 2D cine scans easily consume more than 10 minutes, require greater technologist skill, and significant...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001