Metal block augmentation for bone defects of the medial tibia during primary total knee arthroplasty

نویسندگان

  • Sachiyuki Tsukada
  • Motohiro Wakui
  • Munenori Matsueda
چکیده

BACKGROUND Stable and well-aligned placement of tibial components during primary total knee arthroplasty is challenging in patients with bone defects. Although rectangular block-shaped augmentations are widely used to reduce the shearing force between the tibial tray and bone compared with wedge-shaped augmentations, the clinical result remains unclear. This study aimed to evaluate the outcome of primary total knee arthroplasty with metal block augmentation. METHODS We retrospectively reviewed the 3- to 6-year follow-up results of 33 knees that underwent total knee arthroplasty with metal block augmentation (metal-augmented group) for bone defects of the medial tibia and 132 varus knees without bone defects as the control group. All surgeries were performed using posterior-stabilized cemented prostheses in both groups. Cemented stems were routinely augmented when the metal block was used. RESULTS There were no differences in implant survival rates (100% in metal-augmented and 99.2% in control) or knee function scores (82 points in metal-augmented and 84 points in control) between the two groups at the final follow-up examination (P = 0.60 and P = 0.09, respectively). No subsidence or loosening of the tibial tray was observed. Of 33 metal-augmented total knee arthroplasties, a nonprogressive radiolucent line beneath the metal was detected in 10 knees (30.3%), and rounding of the medial edge of the tibia was observed in 17 knees (51.5%). CONCLUSIONS The clinical results of total knee arthroplasty with metal augmentation were not inferior to those in patients without bone defects. However, radiolucent lines were observed in 30.3%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Management of severe tibial bony defects with double metal blocks in knee arthroplasty—a technical note involving 9 cases

Open Access This article is distributed under the terms of the Creative Commons Attribution Noncommercial License which permits any noncommercial use, distribution, and reproduction in any medium, provided the source is credited. DOI 10.3109/17453674.2010.548031 Severe bony defects during either primary or revision knee arthroplasty are common. If the defect is > 10 mm in its greatest depth, me...

متن کامل

Management of Tibial Bony Defect with Metal Block in Primary Total Knee Replacement Arthroplasty

PURPOSE To analyze minimum 2-year clinical and radiological follow-up results of primary total knee replacement arthroplasty (TKRA) with metal block augmentation for tibial bony defect. MATERIALS AND METHODS We analyzed 67 cases (52 patients) of primary TKRA with metal block augmentation for tibial bony defects from March 1999 and March 2008. Clinical results were evaluated using the Knee Soc...

متن کامل

Management of tibial bone defects with metal augmentation in primary total knee replacement: a minimum five-year review.

Bone defects are occasionally encountered during primary total knee replacement (TKR) and cause difficulty in establishing a stable well-aligned bone-implant interface. Between March 1999 and November 2005, 59 knees in 43 patients underwent primary TKR with a metal block augmentation for tibial bone deficiency. In all, six patients (eight knees) died less than four years post-operatively, and f...

متن کامل

Mid-term clinical results of primary total knee arthroplasty using metal block augmentation and stem extension in patients with rheumatoid arthritis

BACKGROUND Despite recent advancements in rheumatoid arthritis (RA) pharmacotherapy, surgeons still encounter severely damaged knees. The purpose of the present study was to analyze the mid-term clinical results of total knee arthroplasty (TKA) with metal block augmentation and stem extension. METHODS A total of 26 knees in 21 patients who underwent primary TKA with metal block augmentation a...

متن کامل

A Comparative Biomechanical Analysis

J Bone Joint Surg [Br] 2009;91-B:271-7. Received 16 June 2008; Accepted after revision 26 September 2008 The treatment of bony defects of the tibia at the time of revision total knee replacement is controversial. The place of compacted morsellised bone graft is becoming established, particularly in contained defects. It has previously been shown that the initial stability of impaction-grafted t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 8  شماره 

صفحات  -

تاریخ انتشار 2013