Closed Loop Control of a Tethered Magnetic Capsule Endoscope

نویسندگان

  • Addisu Z. Taddese
  • Piotr R. Slawinski
  • Keith Obstein
  • Pietro Valdastri
چکیده

Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Nonholonomic Closed-loop Velocity Control of a Soft-tethered Magnetic Endoscope

In this paper, we demonstrate velocity-level closedloop control of a tethered magnetic capsule endoscope that is actuated via serial manipulator with a permanent magnet at its end-effector. Closed-loop control (2 degrees-of-freedom in position, and 2 in orientation) is made possible with the use of a real-time magnetic localization algorithm that utilizes the actuating magnetic field and thus d...

متن کامل

Five-degree-of-freedom manipulation of an untethered magnetic device in fluid using a single permanent magnet with application in stomach capsule endoscopy

This paper demonstrates magnetic three-degree-of-freedom (3-DOF) closed-loop position and 2-DOF open-loop orientation control of a mockup magnetic capsule endoscope in fluid with a single permanent magnet positioned by a commercial 6-DOF robotic manipulator, using feedback of only the 3-DOF capsule position measured by a localization system, with application in capsule endoscopy of a fluid-dist...

متن کامل

5-DOF Manipulation of an Untethered Magnetic Device in Fluid using a Single Permanent Magnet

This paper presents a three degree-of-freedom (3DOF) closed-loop position and 2-DOF open-loop orientation control method for an untethered mockup magnetic capsule endoscope in fluid with a single permanent magnet positioned by a commercial robotic manipulator and a 3-DOF capsuleposition localization system. Using traditional methods known to roboticists, we study the kinematics of untethered ma...

متن کامل

A Pilot Trial of Ambulatory Monitoring of Gastric Motility Using a Modified Magnetic Capsule Endoscope

The magnetic capsule endoscope has been modified to be fixed inside the stomach and to monitor the gastric motility. This pilot trial was designed to investigate the feasibility of the magnetic capsule endoscope for monitoring gastric motility. The magnetic capsule endoscope was swallowed by the healthy volunteer and maneuvered by the external magnet on his abdomen surface inside the stomach. T...

متن کامل

5-DOF Manipulation of a Magnetic Capsule in Fluid using a Single Permanent Magnet: Proof-of-Concept for Stomach Endoscopy

Magnetic manipulation of capsule endoscopes has the potential to make current gastrointestinal screening procedures faster, safer, and less invasive. To date, two electromagnetic systems have been developed with the ability to perform five-degree-of-freedom (5-DOF) manipulation of an untethered magnetic device such as a magnetic capsule endoscope: the OctoMag system consists of eight electromag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Robotics science and systems : online proceedings

دوره 2016  شماره 

صفحات  -

تاریخ انتشار 2016