Attenuation correction using combination of a parallel hole collimator and an uncollimated non-uniform line array source.
نویسندگان
چکیده
Attenuation correction is very important for quantitative SPECT imaging. We designed an uncollimated non-uniform line array source (non-uniform LAS) for attenuation correction based on transmission computed tomography (TCT) using Tc-99m and compared its performance with an uncollimated uniform line array source (uniform LAS) in a thorax phantom study. This non-uniform LAS was attached to one camera head of a dual-head gamma camera, and transmission data were acquired with another camera head with a low-energy, general purpose, parallel-hole collimator at 50 cm-distance apart from the source. The modified TEW using a subtraction factor of 1.0 was employed to correct scattered Tc-99m photons for transmission data. In the phantom experiment, eight TCT data were acquired with the scanning time changed from 2 minutes to 20 minutes for each LAS. The Tc-99m attenuation coefficient (mu) maps with the non-uniform LAS and uniform LAS improved the statistical count variation in the mediastinum filled with water as the scanning time got longer. The Tc-99m mu-map with the non-uniform LAS and 6 minutes of scanning time had equal quality at the center of the thorax phantom to that with the uniform LAS and 16 minutes of scanning time. In conclusion, for the TCT imaging with combination of the parallel hole collimator and uncollimated Tc-99m external source the non-uniform LAS can reduce the Tc-99m radioactivity or the TCT scanning time compared with the uniform LAS.
منابع مشابه
Optimization of an ultra-high-resolution rectangular pixelated parallel-hole collimator with a CZT pixelated semiconductor detector for HiRe-SPECT system
Introduction: In nuclear medicine, the use of a pixelated semiconductor detector such as CZT is an of growing interest for introducing new devices. Especially, the spatial resolution can be improved by using a pixelated parallel-hole collimator with equal holes and pixel sizes based on the pixelated detector. The purpose of this study was to compare the effect of pixelated and ...
متن کاملEvaluation of the Reconstruction Parameters of Brain Dopamine Transporter SPECT Images Obtained by a Fan Beam Collimator: A Comparison with Parallel-hole Collimators
Objective(s): The purpose of this study was to examine the optimal reconstruction parameters for brain dopamine transporter SPECT images obtained with a fan beam collimator and compare the results with those obtained by using parallel-hole collimators.Methods: Data acquisition was performed using two SPECT/CT devices, namely a Symbia T6 and an Infinia Hawkeye 4 (device A and B) equipped with fa...
متن کاملAn analytical approach to quantitative reconstruction of non-uniform attenuated brain SPECT.
An analytical approach to quantitative brain SPECT (single-photon-emission computed tomography) with non-uniform attenuation is developed. The approach formulates accurately the projection-transform equation as a summation of primary- and scatter-photon contributions. The scatter contribution can be estimated using the multiple-energy-window samples and removed from the primary-energy-window da...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملThe evaluation of slant hole collimator in myocardial perfusion SPECT: a simulation study
Introduction: We have investigated cardiac SPECT with slant hole collimator in which the holes are slanted towards the target organ, to provide greater sensitivity over the parallel hole collimator. In addition, parallel hole collimator was used to obtain a comparison in FWHM, sensitivity, Compton and photoelectric area values in the simulations. Materials and Methods...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Annals of nuclear medicine
دوره 18 5 شماره
صفحات -
تاریخ انتشار 2004