High sensitivity PCR assay in plastic micro reactors.

نویسندگان

  • Jianing Yang
  • Yingjie Liu
  • Cory B Rauch
  • Rauch L Stevens
  • Randall H Liu
  • Robin Lenigk
  • Piotr Grodzinski
چکیده

Small volume operation and rapid thermal cycling have been subjects of numerous reports in micro reactor chip development. Sensitivity aspects of the micro PCR reactor have not been studied in detail, however, despite the fact that detection of rare targets or trace genomic material from clinical and/or environmental samples has been a great challenge for microfluidic devices. In this study, a serpentine shaped thin (0.75 mm) polycarbonate plastic PCR micro reactor was designed, constructed, and tested for not only its rapid operation and efficiency, but also its detection sensitivity and specificity, in amplification of Escherichia coli (E. coli) K12-specific gene fragment. At a template concentration as low as 10 E. coli cells (equivalent to 50 fg genomic DNA), a K12-specific gene product (221 bp) was adequately amplified with a total of 30 cycles in 30 min. Sensitivity of the PCR micro reactor was demonstrated with its ability to amplify K12-specific gene from 10 cells in the presence of 2% blood. Specificity of the polycarbonate PCR micro reactor was also proven through multiplex PCR and/or amplification of different pathogen-specific genes. This is, to our knowledge, the first systematic study of assay sensitivity and specificity performed in plastic, disposable micro PCR devices.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development of qRT-PCR Test for Quantification of Rubella Virus in Commercially Available Vaccines

vaccines is considered as a critical point and in-process of quality control (IPQC) test of vaccine production. Rapid tests, like real time PCR, are more appropriated when the production occurs at industrial scale because of the amounts of starting materials and the excess of consumed time required. In the current study, a real-time quantitative reverse transcription-polymerase chain reaction...

متن کامل

Evaluation of the ICT malaria P.f/P.v and the OptiMal rapid diagnostic tests for malaria in febrile returned travellers.

Rapid diagnostic tests (RDTs) are less reliant on expert microscopy and have the potential to reduce errors in malaria diagnosis but have not been extensively evaluated in nonimmune persons or in countries where infection is not endemic. We evaluated the ICT P.f/P.v (ICT-Amrad, Sydney, Australia) and OptiMal (Flow Inc., Portland, Oreg.) assays prospectively for the diagnosis of malaria in 158 s...

متن کامل

Detection and enumeration of Cryptosporidium oocysts in environmental water samples by Real-time PCR assay

Introduction: The protozoan parasite, Cryptosporidium Spp., widely spreads in both raw and drinking waters. It is the causative agents of waterborne diarrhea and gastroenteritis in the world. In the present study, a molecular assay was used for the detection and quantification of Cryptosporidium oocysts in environmental water samples. Materials and methods: Thirty surface water samples wer...

متن کامل

Evaluation of in-house polymerase chain reaction assay sensitivity, can it be utilized in limited-resources settings?

  Background :Polymerase chain reaction (PCR) assay has widely used for the detection of tuberculosis (TB). This study tried to compare in-house PCR with some well-known commercial PCR kits for detection of TB agent.   Methods : Clinical samples obtained from 620 TB suspected patients were analyzed for the diagnosis of Mycobacterium tuberculosis complex (MTC) by in-house PCR. All samples were o...

متن کامل

Calibrated real-time PCR assay for quantitation of human herpesvirus 8 DNA in biological fluids.

Accurate laboratory tests for the diagnosis of active human herpesvirus 8 (HHV-8) infection are becoming essential to study the pathogenesis of HHV-8-associated tumors and for the clinical management of HHV-8-infected individuals. We have developed a highly sensitive, calibrated quantitative real-time PCR assay for the measurement of cell-free HHV-8 DNA in body fluids, based on the addition of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Lab on a chip

دوره 2 4  شماره 

صفحات  -

تاریخ انتشار 2002