Reliability Of A Novel Intracardiac Electrogram Method For AV And VV Delay Optimization And Comparability To Echocardiography Procedure For Determining Optimal Conduction Delays In CRT Patients
نویسندگان
چکیده
BACKGROUND Echocardiography is widely used to optimize CRT programming. A novel intracardiac electrogram method (IEGM) was recently developed as an automated programmer-based method, designed to calculate optimal atrioventricular (AV) and interventricular (VV) delays and provide optimized delay values as an alternative to standard echocardiographic assessment. OBJECTIVE This study was aimed at determining the reliability of this new method. Furthermore the comparability of IEGM to existing echocardiographic parameters for determining optimal conduction delays was verified. METHODS Eleven patients (age 62.9+/- 8.7; 81% male; 73% ischemic), previously implanted with a cardiac resynchronisation therapy defibrillator (CRT-D) underwent both echocardiographic and IEGM-based delay optimization. RESULTS Applying the IEGM method, concordance of three consecutively performed measurements was found in 3 (27%) patients for AV delay and in 5 (45%) patients for VV delay. Intra-individual variation between three measurements as assessed by the IEGM technique was up to 20 ms (AV: n=6; VV: n=4). E-wave, diastolic filling time and septal-to-lateral wall motion delay emerged as significantly different between the echo and IEGM optimization techniques (p < 0.05). The final AV delay setting was significantly different between both methods (echo: 126.4 +/- 29.4 ms, IEGM: 183.6 +/- 16.3 ms; p < 0.001; correlation: R = 0.573, p = 0.066). VV delay showed significant differences for optimized delays (echo: 46.4 +/- 23.8 ms, IEGM: 10.9 +/- 7.0 ms; p <0.01; correlation: R = -0.278, p = 0.407). CONCLUSION The automated programmer-based IEGM-based method provides a simple and safe method to perform CRT optimization. However, the reliability of this method appears to be limited. Thus, it remains difficult for the examiner to determine the optimal hemodynamic settings. Additionally, as there was no correlation between the optimal AV- and VV-delays calculated by the IEGM method and the echo optimization, the use of the IEGM method and the comparability to the echo has not been definitely clarified.
منابع مشابه
Cardiac resynchronization therapy during rest and exercise: comparison of two optimization methods
AIMS Optimal exercise programming of cardiac resynchronization therapy (CRT) devices is unknown. We aimed to: (i) investigate variations in optimal atrioventricular (AV) and interventricular (VV) delays from rest to exercise, assessed by both echocardiography and an automated intracardiac electrogram (IEGM) method; (ii) evaluate the acute haemodynamic impact of CRT optimization performed during...
متن کاملAcute Beneficial Hemodynamic Effects of a Novel 3D-Echocardiographic Optimization Protocol in Cardiac Resynchronization Therapy
BACKGROUND Post-implantation therapies to optimize cardiac resynchronization therapy (CRT) focus on adjustments of the atrio-ventricular (AV) delay and ventricular-to-ventricular (VV) interval. However, there is little consensus on how to achieve best resynchronization with these parameters. The aim of this study was to examine a novel combination of doppler echocardiography (DE) and three-dime...
متن کاملComparison between IEGM-based approach and echocardiography in AV/PV and VV delay optimization in CRT-D recipients (Quicksept study)
BACKGROUND AtrioVentricular (AV) and InterVentricular (VV) delay optimization can improve ventricular function in Cardiac Resynchronization Therapy (CRT) and is usually performed by means of echocardiography. St Jude Medical has developed an automated algorhythm which calculates the optimal AV and VV delays (QuickOpt™) based on Intracardiac ElectroGrams, (IEGM), within 2 min. So far, the effica...
متن کاملWhether noninvasive optimization of AV and VV delays improves the response to cardiac resynchronization therapy.
BACKGROUND Device optimization is not routinely performed in patients who underwent cardiac resynchronization therapy (CRT) device implantation. Noninvasive optimization of CRT devices by measurement of cardiac output (CO) can be used as a simple method to assess ventricular systolic performance. The aim of this study was to assess whether optimization of atrioventricular (AV) and interventricu...
متن کاملEchocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization.
An optimized atrioventricular (AV) interval can maximize the benefits of cardiac resynchronization therapy (CRT). If programmed poorly, it may curtail beneficial effects of CRT. AV optimization will not convert non-responder to responder, but may convert under-responder to improved status. There are many echocardiographic techniques for AV optimization but there is no universally accepted gold ...
متن کامل