A Noninvasive Alternative to Swan-Ganz Catheter

نویسندگان

  • Pier Luigi Temporelli
  • Ermanno Eleuteri
چکیده

Background—Although several studies have demonstrated a good correlation between Doppler echocardiographic and invasive measurements of single hemodynamic variables, the accuracy of echocardiography in providing a comprehensive assessment in individual patients has not been validated. The aim of this study was to assess the accuracy and clinical applicability of Doppler echocardiography in determining the entire hemodynamic profile in stable patients with advanced systolic heart failure. Methods and Results—Doppler echocardiography and Swan-Ganz catheterization were simultaneously performed in 43 consecutive patients with advanced heart failure. Echocardiographic data required for estimation of right atrial, pulmonary artery systolic, and pulmonary capillary wedge pressures; cardiac output; and pulmonary vascular resistance were obtained and compared with hemodynamic data. For all variables, invasive and noninvasive hemodynamic values were highly correlated (P 0.0001), with very low bias and narrow 95% confidence limits. In 16 patients with elevated pulmonary vascular resistance ( 3 Wood U) and pulmonary capillary wedge pressures ( 20 mm Hg) at baseline, hemodynamic and Doppler measurements were simultaneously repeated after unloading manipulations. Absolute values and changes of pulmonary vascular resistance and pulmonary capillary wedge pressures after unloading were still accurately predicted (r 0.96 and r 0.92, respectively). Conclusions—Doppler echocardiography may offer a valid alternative to invasive cardiac catheterization for the comprehensive hemodynamic assessment of patients with advanced heart failure, and it may assist in monitoring and optimization of therapy in potential heart transplant recipients. (Circ Heart Fail. 2010;3:387-394.)

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Doppler echocardiography in advanced systolic heart failure: a reliable noninvasive alternative to Swan-Ganz catheter

Background: Although several studies have demonstrated a good correlation between Doppler echocardiographic and invasive measurements of single hemodynamic variables, the accuracy of echocardiography in providing a comprehensive assessment in individual patients has not been validated. To assess the accuracy and clinical applicability of Doppler echocardiography in determining the entire hemody...

متن کامل

Entrapment of a Swan-Ganz catheter.

Failure to withdraw a catheter is related primarily to catheter entrapment or knotting. Placement of a Swan-Ganz catheter is associated with various complications, one of which is entrapment. Entrapment of a Swan-Ganz catheter in the heart, vena cava, or pulmonary artery is a very rare and serious complication that may lead to life-threatening complications if not treated appropriately. Most re...

متن کامل

Latex anaphylaxis caused by a Swan-Ganz catheter.

A 78-year-old woman visited the division of cardiovascular disease in our hospital. She underwent a cardiac catheter examination, and a Swan-Ganz catheter was inserted. Several minutes later, she developed anaphylactic shock. She had no past history of latex allergy, but did have a banana allergy. Skin prick tests showed a positive reaction to an extract of latex gloves and an extract of the ba...

متن کامل

Pulmonary artery rupture as a complication of Swan-Ganz catheter application. Diagnosis and endovascular treatment: a single centre's experience

INTRODUCTION The placement of a Swan-Ganz catheter into the pulmonary artery may lead to a number of complications (2-17%). In less than 0.2% of cases Swan-Ganz catheterization results in serious vascular damage - pulmonary artery rupture (PAR). This paper presents two distinct forms of iatrogenic PAR treated endovascularly using different vascular devices. AIM To evaluate the effectiveness o...

متن کامل

Hepatic vein obstruction due to Swan-Ganz catheter placement.

Complications from Swan-Ganz catheters during insertion, long-term placement, or removal have been known since its development. I describe the unusual presentation of a pacing Swan-Ganz catheter mispositioned into the hepatic vein producing vascular obstruction, yet with adequate cardiac pacing.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010