Different implant impression techniques for edentulous patients treated with CAD/CAM complete-arch prostheses: a randomised controlled trial reporting data at 3 year post-loading.
نویسندگان
چکیده
PURPOSE To compare two different impression techniques for implants in totally edentulous patients. MATERIALS AND METHODS A total of 38 patients had impressions taken both using plaster and splinted vinyl polysiloxane (splinted-VPS). Two casts per patient were generated and allocated as test (plaster) and control (splinted-VPS) cast groups according to a randomised cross-over design. One of the two casts from each patient was randomly selected as master cast according to a parallelgroup design and used to fabricate the definitive prosthesis. Outcome measures were implant and prosthetic success rates, complications, marginal bone level (MBL) changes, patient satisfaction, chair time required to take the impressions, inter-implant discrepancy between the casts, sulcus bleeding index (SBI) and plaque score (PS). RESULTS In total, 76 impressions were taken in 38 patients. Two plaster impressions failed. Furthermore, 38 computer-aided design/computer-assisted manufacturing screw-retained complete-arch prostheses were fabricated onto the master cast (18 from plaster and 20 from splinted-VPS impressions) and the patients were followed up for 3 years after loading. No drop-out occurred and no implants or prostheses failed, accounting for a cumulative implant and prosthesis survival rate of 100% over the 3-year post-loading period. Plaster impressions yielded significantly greater patient satisfaction and shorter chair time. The discrepancy between the casts was 0.055 ± 0.067 mm (P = 0.931). Mixed model analysis revealed a significant main effect from both the implant number and the inter-implant distance, while no difference was found with regard to implant angulation. Five chip-off fractures of the porcelain veneer occurred in 5 of the 38 patients (3 in restorations fabricated onto the plaster cast group and 2 in the splinted-VPS cast group) with no effect from the type of impression on the prosthetic success rate (P = 0.331). However, all of the patients were functionally and aesthetically satisfied with their prostheses. Furthermore, mean MBL, SBI and PS showed no significant differences (P > 0.05) between the groups. CONCLUSIONS The clinical outcome of plaster impressions for completely edentulous patients was found to be the same as that for splinted-VPS impressions. The intraoral pre-scan resin framework try-in can be avoided. Plaster impressions may be less time consuming and thus more comfortable for the patient, but sometimes may have to be repeated due to fractures. CONFLICT-OF-INTEREST STATEMENT All materials used in this study were purchased by the authors and there were no commercial or institutional interests.
منابع مشابه
Digital protocol for reference-based guided surgery and immediate loading: a prospective clinical study.
PURPOSE To evaluate the performance of a computer-aided three-dimensional planning protocol in combination with previously inserted reference mini-implants and CAD/CAM technology to restore completely edentulous patients. The study evaluated implant and superstructure survival in a prospective clinical trial. MATERIALS AND METHODS The plan protocol called for treatment of 35 patients who were...
متن کاملAccelerated treatment protocols: full arch treatment with interim and definitive prostheses.
With the advent of titanium, root form implants and osseointegration, dental treatment has undergone a metamorphosis in recent years. These new techniques enable dentists to provide anchorage for various kinds of prostheses that improve masticatory function, esthetics, and comfort for patients. Implant treatment protocols have been improved relative to implant macro- and micro-geometries, surgi...
متن کاملOn the role of number of fixtures, surgical technique and timing of loading.
AIMS The aims of this thesis were to analyze reduced number of implants supporting full arch fixed mandibular prostheses and fixed partial dentures (FPDs), non-submerged healing and early loading in the edentulous mandible. A further aim was to evaluate fit of Computer Numerical Controlled (CNC) milled I-Bridge frameworks. MATERIAL & METHODS Paper I. One hundred and nineteen patients rehabili...
متن کاملEffect of splinted and nonsplinted impression techniques on the accuracy of fit of fixed implant prostheses in edentulous patients: a comparative study.
PURPOSE The effect of different implant impression techniques on the accuracy of casts has been investigated mostly in vitro, and clinically relevant evidence is scarce. The purpose of this study was to investigate the effect of implant impression techniques--specifically, splinted versus nonsplinted--on the accuracy of fit of fixed implant prostheses in edentulous patients. MATERIALS AND MET...
متن کاملImmediate, early (6 weeks) and delayed loading (3 months) of single implants: 4-month post-loading from a multicenter pragmatic randomised controlled trial.
PURPOSE To compare the clinical outcome of single, partial and full fixed implant-supported prostheses immediately loaded (within 48 h), early loaded at 6 weeks and conventionally loaded at 3 months (delayed loading). MATERIALS AND METHODS Eighty-one patients (27 requiring single implants, 27 requiring partial fixed prostheses and 27 requiring total fixed cross-arch prostheses) were randomise...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- European journal of oral implantology
دوره 6 4 شماره
صفحات -
تاریخ انتشار 2013