Remarks on reporting and recording consistent with the ICRU Reference Dose
نویسندگان
چکیده
BACKGROUND ICRU 50/62 provides a framework to facilitate the reporting of external beam radiotherapy treatments from different institutions. A predominant role is played by points that represent "the PTV dose". However, for new techniques like Intensity Modulated Radiotherapy (IMRT) - especially step and shoot IMRT - it is difficult to define a point whose dose can be called "characteristic" of the PTV dose distribution. Therefore different volume based methods of reporting of the prescribed dose are in use worldwide. Several of them were compared regarding their usability for IMRT and compatibility with the ICRU Reference Point dose for conformal radiotherapy (CRT) in this study. METHODS The dose distributions of 45 arbitrarily chosen volumes treated by CRT plans and 57 volumes treated by IMRT plans were used for comparison. Some of the IMRT methods distinguish the planning target volume (PTV) and its central part PTVx (PTV minus a margin region of x mm). The reporting of dose prescriptions based on mean and median doses together with the dose to 95% of the considered volume (D95) were compared with each other and in respect of a prescription report with the aid of one or several possible ICRU Reference Points. The correlation between all methods was determined using the standard deviation of the ratio of all possible pairs of prescription reports. In addition the effects of boluses and the characteristics of simultaneous integrated boosts (SIB) were examined. RESULTS Two types of methods result in a high degree of consistency with the hitherto valid ICRU dose reporting concept: the median dose of the PTV and the mean dose to the central part of the PTV (PTVx). The latter is similar to the CTV, if no nested PTVs are used and no patient model surfaces are involved. A reporting of dose prescription using the CTV mean dose tends to overestimate the plateau doses of the lower dose plateaus of SIB plans. PTVx provides the possibility to approach biological effects using the standard deviation of the dose within this volume. CONCLUSION The authors advocate reporting the PTV median dose or preferably the mean dose of the central dose plateau PTVx as a potential replacement or successor of the ICRU Reference Dose - both usable for CRT and IMRT.
منابع مشابه
TH-EF-204-00: AAPM-AMPR (Russia)-SEFM (Spain) Joint Course On Challenges and Advantages of Small Field Radiation Treatment Techniques.
Joanna E. Cygler, Jan Seuntjens, J. Daniel Bourland, M. Saiful Huq, Josep Puxeu Vaque, Daniel Zucca Aparicio, Tatiana Krylova, Yuri Kirpichev, Eric Ford, Caridad Borras Stereotactic Radiation Therapy (SRT) utilizes small static and dynamic (IMRT) fields, to successfully treat malignant and benign diseases using techniques such as Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation T...
متن کامل”Maximum dose” points in cervical and endometrial cancer medium dose rate brachytherapy
Background: Best dose distribution in target volume and control of Organ at Risk (OAR) dose are the two main goals in brachytherapy. Materials and Methods: In this study in vivo dosimetry in 4 rectal points was performed by Transillumination Dosimeter (TLD) s and the measured doses were compared in different patients. One point was reported to have the maximum dose in each patient and the very ...
متن کاملDosimetric evaluation of rectum and bladder using image-based CT planning and orthogonal radiographs with ICRU 38 recommendations in intracavitary brachytherapy
The purpose is to compare CT-based dosimetry with International Commission on Radiation Units and Measurements (ICRU 38) bladder and rectum reference points in patients of carcinoma of uterine cervix treated with intracavitary brachytherapy (ICA). Twenty-two consecutive patients were evaluated. Orthogonal radiographs and CT images were acquired and transferred to PLATO planning system. Bladder ...
متن کاملA study on dosimetry accuracy of Strut-Adjust Volume Implant (SAVI) brachytherapy
Introduction: Accelerated Partial Breast Irradiation (APBI) is an effective treatment for breast carcinomas because of its limited number of fractions. Strut-adjusted volume implant (SAVI) is a HDR brachytherapy applicator to deliver the prescription dose with good PTV coverage and acceptable dose to skin, chest wall and organ at risks. Acceptable clinical outcomes depend on a...
متن کاملQuality improvement guidelines for recording patient radiation dose in the medical record for fluoroscopically guided procedures.
ACR American College of Radiology, CRCPD Conference of Radiation Control Program Directors, FDA Food and Drug Administration, ICRU International Commission on Radiation Units and Measurements, IEC International Electrotechnical Commission, IRP interventional reference point, Ka,r total air kerma at the interventional reference point, NCRP National Council on Radiation Protection and Measurement...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Radiation Oncology (London, England)
دوره 4 شماره
صفحات -
تاریخ انتشار 2009