Performance Comparison of Streak Camera Recording Systems
نویسندگان
چکیده
Performance characteristics of various readout systems coupled to an EGG-AVO streak camera were analyzed and compared to scaling estimates. The purpose of the work was to determine the limits of the streak camera performance and the optimal fielding conditions for the Amador Valley Operations(AV0) streak camera systems. We measured streak camera limitations in spatial resolution and sensitivity. Streak camera limits on spatial resolution are greater than 18 lp/mm at 4% contrast. However, it will be difficult to make use of any resolution greater than this because of high spatial frequency variation in the photocathode sensitivity. We have measured a signal to noise of 3000 with 0.3 mW/cm2 of 830 nm light at a 10 ns/mm sweep speed. We have compared lens coupling systems with and without micro-channel plate intensifiers and systems using film or charge coupled device (CCD) readout. There were no conditions where film was found to be an improvement over the CCD readout. Systems utilizing a CCD readout without an intensifier have comparable resolution, for these source sizes and at a nominal cost in signal to noise of 3, over those with an intensifier. Estimates of the signal-to-noise for different light coupling methods show how performance can be improved. IXSTRIBUTION OF THE DOCUMENT IS UNLJMITE 1
منابع مشابه
Streak camera crosstalk reduction using a multiple delay optical fiber bundle.
The streak camera is one of the fastest photodetection systems, while its capability of multiplexing is particularly attractive to many applications requiring parallel data acquisition. The degree of multiplexing in a streak camera is limited by the crosstalk between input channels. We developed a technique that introducing a fixed time delay between adjacent fiber channels in a customized two-...
متن کاملThe streak camera development program at LLE
The Diagnostic Development Group at the Laboratory for Laser Energetics has endeavored to build a stand-alone, remotely operated streak camera with comprehensive autofocus and self-calibration capability. Designated as the Rochester Optical Streak System (ROSS), it is a generic streak camera platform, capable of accepting a variety of streak tubes. The system performance is limited by the insta...
متن کاملAppropriate energy window width for gamma camera [Persian]
Introduction: Scatter radiation is one of the major sources of error in nuclear medicine data processing. Different methods of scatter correction have been introduced in order to improve the quality of data. However the best method is to avoid recording of scatter photons in acquisition. The only difference between scattered and non-scattered photons is the energy. Pulse height analyzer i...
متن کاملMeasuring 8-250 ps short pulses using a high-speed streak camera on kilojoule, petawatt-class laser systems.
Short-pulse measurements using a streak camera are sensitive to space-charge broadening, which depends on the pulse duration and shape, and on the uniformity of photocathode illumination. An anamorphic-diffuser-based beam-homogenizing system and a space-charge-broadening calibration method were developed to accurately measure short pulses using an optical streak camera. This approach provides a...
متن کاملMegahertz streak-mode Fourier domain optical coherence tomography.
Here we present an ultrahigh-speed Fourier-domain optical coherence tomography (OCT) that records the OCT spectrum in streak mode with a high-speed area scan camera, which allows higher OCT imaging speed than can be achieved with a line-scan camera. Unlike parallel OCT techniques that also use area scan cameras, the conventional single-mode fiber-based point-scanning mechanism is retained to pr...
متن کامل