Stable xenon versus radiolabeled microsphere cerebral blood flow measurements in baboons.
نویسندگان
چکیده
Regional cerebral blood flow was simultaneously determined using the stable xenon computed tomographic and the radioactive microsphere techniques over a wide range of blood flow rates (less than 10-greater than 300 ml/100 g/min) in 12 baboons under conditions of normocapnia, hypocapnia, and hypercapnia. A total of 31 pairs of determinations were made. After anesthetic and surgical preparation of the baboons, cerebral blood flow was repeatedly determined using the stable xenon technique during saturation with 50% xenon in oxygen. Concurrently, cerebral blood flow was determined before and during xenon administration using 15-microns microspheres. In Group 1 (n = 7), xenon and microsphere determinations were made repeatedly during normocapnia. In Group 2 (n = 5), cerebral blood flow was determined using both techniques in each baboon during hypocapnia (PaCO2 = 20 mm Hg), normocapnia (PaCO2 = 40 mm Hg), and hypercapnia (PaCO2 = 60 mm Hg). Xenon and microsphere values in Group 1 were significantly correlated (r = 0.69, p less than 0.01). In Group 2, values from both techniques also correlated closely across all levels of PaCO2 (r = 0.92, p less than 0.001). No significant differences existed between the slopes or y intercepts of the regression lines for either group and the line of identity. Our data indicate that the stable xenon technique yields cerebral blood flow values that correlate well with values determined using radioactive microspheres across a wide range of cerebral blood flow rates.
منابع مشابه
Measurement of cerebral blood flow during xenon inhalation as measured by the microspheres method.
Measurements of cerebral blood flow (CBF) were performed using the microsphere technique in non-human primates (baboons) to assess the effect of non-radioactive xenon gas inhalation on CBF. Blood flows in small tissue volumes (approximately 1 cm3) were directly measured before and during the inhalation of xenon/oxygen gas mixtures. The results of these studies demonstrated that when inhaled in ...
متن کاملComparison of microsphere and Xenon-133 clearance method in measuring skeletal muscle and cerebral blood flow.
In this study, we compared the Xenon-133 (Xe) clearance method with the microsphere method in measurement of skeletal muscle and cerebral blood flow (CBF). Over a wide range of flows (1-47 ml/min x 100 g), we compared these two methods with direct measurements of venous outflow in the gracilis muscle. Regression equations relating the Xe (stochastic method) and microsphere measurements of flow ...
متن کاملEffect of stable xenon in room air on regional cerebral blood flow and electroencephalogram in normal baboons.
Measurement of regional cerebral blood flow (rCBF) was performed in 6 healthy baboons during ventilation with 35% stable xenon in artificial air. rCBF was measured with the intraarterial xenon-133 method. EEG was recorded continuously. All CBF areas of interest over one hemisphere reacted in the same way. Mean flow increased during short-term exposure to stable xenon and decreased if stable xen...
متن کاملStable xenon enhanced computed tomography in the study of clinical and pathologic correlates of focal ischemia in baboons.
When the lateral striate arteries of baboons are occluded, an immediate cessation of blood flow followed by a transient, minimal restitution of flow occurs in that vascular distribution. These findings are evident from serial xenon/computed tomography cerebral blood flow imaging. In our study, infarction consistently accompanied arterial occlusion for 6 hours or more. The xenon/computed tomogra...
متن کاملXenon-Enhanced Computed Tomography Compared With [C]Iodoantipyrine for Normal and Low Cerebral Blood Flow States in Baboons
The correlation between the acute, invasive diffusible [C]iodoantipyrine technique for cerebral blood flow and the noninvasive xenon-enhanced computed tomographic method has been assessed by simultaneous measurements in the baboon. Blood flows in small tissue volumes (about 0.125 cm) were directly compared in normal and low flow states. These studies demonstrate a statistically significant asso...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Stroke
دوره 20 12 شماره
صفحات -
تاریخ انتشار 1989