Small-diameter titanium grade IV and titanium-zirconium implants in edentulous mandibles: five-year results from a double-blind, randomized controlled trial

نویسندگان

  • Frauke Müller
  • Bilal Al-Nawas
  • Stefano Storelli
  • Marc Quirynen
  • Stefan Hicklin
  • Jose Castro-Laza
  • Renzo Bassetti
  • Martin Schimmel
چکیده

OBJECTIVE The aim of this study was to compare crestal bone-level changes, soft tissue parameters and implant success and survival between small-diameter implants made of titanium/zirconium (TiZr) alloy or of Grade IV titanium (Ti) in edentulous mandibles restored with removable overdentures. MATERIALS AND METHODS This was a randomized, controlled, double-blind, split-mouth multicenter clinical trial. Patients with edentulous mandibles received two Straumann bone-level implants (diameter 3.3 mm), one of Ti Grade IV (control) and one of TiZr (test), in the interforaminal region. Implants were loaded after 6-8 weeks and removable Locator-retained overdentures were placed within 2 weeks of loading. Modified plaque and sulcus bleeding indices, radiographic bone level, and implant survival and success were evaluated up to 36 months. RESULTS Of 91 treated patients, 75 completed the three-year follow-up. Three implants were lost (two control and one test implant). The survival rates were 98.7% and 97.3%, and the mean marginal bone level change was -0.78 ± 0.75 and -0.60 ± 0.71 mm for TiZr and Ti Grade IV implants. Most patients had a plaque score of 0 or 1 (54% for test and 51.7% for control), and a sulcus bleeding score of 0 (46.1% for test and 44.9% for control). No significant differences were found between the two implant types for bone-level change, soft tissue parameters, survival and success. CONCLUSIONS After 36 months, similar outcomes were found between Ti Grade IV and TiZr implants. The results confirm that the results seen at 12 months continue over time.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review of Titanium Zirconium (TiZr) Alloys for Use in Endosseous Dental Implants

Dental implants made from binary titanium-zirconium (TiZr) alloys have shown promise as a high strength, yet biocompatible alternative to pure titanium, particularly for applications requiring small diameter implants. The aim of this review is to summarize existing literature reporting on the use of binary TiZr alloys for endosseous dental implant applications as tested in vitro, in animals and...

متن کامل

Randomized multicenter comparison of 2 IMZ and 4 TPS screw implants supporting bar-retained overdentures in 425 edentulous mandibles.

PURPOSE Two treatment concepts for implant-supported bar retention of mandibular overdentures-2 intramobile cylinder (IMZ) implants and a Dolder bar and 4 titanium plasma-sprayed (TPS) screw implants and an angulated bar-were compared in a randomized controlled clinical trial with respect to postprosthetic efficacy and safety. MATERIALS AND METHODS Four hundred twenty-five patients with edent...

متن کامل

One-year results of maxillary overdentures supported by 2 titanium-zirconium implants - implant survival rates and radiographic outcomes.

OBJECTIVE To assess implant survival rates and peri-implant bone loss of 2 titanium-zirconium implants supporting maxillary overdentures at 1 year of loading. MATERIAL AND METHODS Twenty maxillary edentulous patients (5 women and 15 men) being dissatisfied with their complete dentures were included. In total, 40 diameter-reduced titanium-zirconium implants were placed in the anterior maxilla....

متن کامل

Clinical and radiographic evaluation of narrow-diameter titanium-zirconium implants in unilateral atrophic mandibular distal extensions: a 1-year pilot study.

BACKGROUND The use of endosseous dental implants has led to more sophisticated fxed options when considering treatment of patients with distal extensions. The use of narrow-diameter implants may reduce the necessity for bone augmentation. The mechanical strength of titanium is limited, so titanium alloys with greater tensile and fatigue strength may be preferable. PURPOSE The purpose of this ...

متن کامل

A comparison of 3 different endosseous nonsubmerged implants in edentulous mandibles: a clinical report.

The purpose of this prospective clinical study was to investigate the outcome of 3 different types of endosseous, nonsubmerged implants in the anterior part of the mandible. Fourteen older edentulous patients, 10 females and 4 males, were included. All participants received 3 different types of endosseous implants in the anterior mandible: 1 titanium plasma-sprayed cylindric implant (4 mm in di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2015