Achieving proposed federal concentrations using reduced specimen volume for the extraction of amphetamines from oral fluid.

نویسندگان

  • Christine Moore
  • Cynthia Coulter
  • Katherine Crompton
چکیده

This article details the rapid extraction of amphetamines from oral fluid using low specimen volume, low sorbent bed mass, and fast gas chromatography with mass selective detection. The collection of a known amount of sample volume coupled with high percentage recovery of drug from the collection pad has allowed oral fluid to be increasingly employed as the specimen of choice for the detection of drug use in various applications. Additionally, low specimen volume for confirmation is required, so that adequate test volume remains for second analysis in case of batch failure or for testing at a different laboratory facility. The extracts were prepared using low bed mass sorbent, so less conditioning, washing, and elution solvent further reduced the overall cost of sample preparation. The limits of quantitation for the assay were 25 ng/mL; the intraday precision of the assays (n = 5) ranged from 0.3 to 3.99%; interday precision ranged from 0.72 to 4.6% for the amphetamine class. The percentage recovery of the drugs from the collection pads ranged from 85.4 to 89.1% (n = 6). The process lends itself to widely available automated processing instrumentation and significantly increases the efficiency of laboratories providing high-volume oral fluid analysis for drugs of abuse.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Oral fluid collection: the neglected variable in oral fluid testing.

The potential to use oral fluid as a drug-testing specimen has been the subject of considerable scientific interest. The ease with which specimens can be collected and the potential for oral fluid (OF) drug concentrations to reflect blood-drug concentrations make it a potentially valuable specimen in clinical as well as forensic settings. However, the possible effects of the OF collection proce...

متن کامل

Oral fluid drug testing of chronic pain patients. I. Positive prevalence rates of licit and illicit drugs.

Oral fluid compliance monitoring of chronic pain patients is an analytical challenge because of the limited specimen volume and the number of drugs that require detection. This study evaluated oral fluid for monitoring pain patients and compared results to urine studies of similar populations. Oral fluid specimens were analyzed from 6441 pain patients from 231 pain clinics in 20 states. Specime...

متن کامل

Identification and quantitation of amphetamines, cocaine, opiates, and phencyclidine in oral fluid by liquid chromatography-tandem mass spectrometry.

Analytical methods for measuring multiple licit and illicit drugs and metabolites in oral fluid require high sensitivity, specificity, and accuracy. With the limited volume available for testing, comprehensive methodology is needed for simultaneous measurement of multiple analytes in a single aliquot. This report describes the validation of a semi-automated method for the simultaneous extractio...

متن کامل

December 2012

ith the aging population and recognition that treatment of a patient’s pain is a key healthcare objective, more patients are taking pain medications that must be taken consistently to be effective. But at the same time, many of these same medications are subject to abuse. These benefits and dangers drive the need to test for patient compliance. Although urine has historically been the specimen ...

متن کامل

Oral fluid testing for drugs of abuse: positive prevalence rates by Intercept immunoassay screening and GC-MS-MS confirmation and suggested cutoff concentrations.

Draft guidelines for the use of oral fluid for workplace drug testing are under development by the Substance Abuse and Mental Health Services Administration (SAMHSA) in cooperation with industry and researchers. Comparison studies of the effectiveness of oral fluid testing versus urine testing are needed to establish scientifically reliable cutoff concentrations for oral fluid testing. We prese...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of analytical toxicology

دوره 31 8  شماره 

صفحات  -

تاریخ انتشار 2007