Some factors affecting separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection.
نویسندگان
چکیده
Some factors influencing the separation and detection of amino acids by high-performance anion-exchange chromatography with integrated pulsed amperometric detection were investigated. These factors include eluent concentration, column temperature, and detection waveform. The selectivity changes in weakly retained amino acids are slight with changing sodium hydroxide eluent concentration. When sodium acetate eluent concentration is changed, the selectivity variations between strongly retained amino acids containing two carboxyl groups and containing only one carboxyl group are obviously different. Significant but slight selectivity changes in weakly retained amino acids can be achieved through changing the column temperature. Sodium hydroxide and sodium acetate eluent concentration affect the detection of amino acids. Detection sensitivity of amino acids can be improved by increasing the concentration of sodium hydroxide and sodium acetate in a certain concentration range. The detections of amino acids at two different detection waveforms were compared. The hydroxyl amino acids can be selectively detected by choosing a modified detection waveform. The optimized gradient elution condition and column temperature for analyzing 19 amino acids were obtained. The time for the gradient elution program was 60 min. The column temperature was 35 degrees C. Under the optimized conditions, detection limits for 19 amino acids were 0.15-4.52 pmol. The calibration graphs of peak area for all the analytes were linear for about three orders of magnitude. The RSDs (n=5) of peak area were 0.6-5.6%. The determination of trace amino acid impurities in valine product is shown as an application example.
منابع مشابه
Direct amino acid analysis method for speciation of selenoamino acids using high-performance anion-exchange chromatography coupled with integrated pulsed amperometric detection.
Speciation analysis of selenomethylcysteine (SeMeCys), selenomethionine (SeMet) and selenocystine (SeCys) has been performed using a direct amino acid analysis method with high-performance anion-exchange chromatography (HPAEC) coupled with integrated pulsed amperometric detection (IPAD). Three selenoamino acids could be baseline-separated from 19 amino acids using gradient elution conditions fo...
متن کاملHigh-pressure liquid chromatography of sialic acids on a pellicular resin anion-exchange column with pulsed amperometric detection: a comparison with six other systems.
A wide variety of different sialic acids have been reported in nature. Following their release and purification, detection and quantitation of these molecules is now possible by a number of techniques. We and others have previously reported high-pressure liquid chromatography separation of sialic acids with several different columns, elution methods, and detection techniques. We report here a n...
متن کاملSimultaneous Separation and Quantitative Determination of Monosaccharides, Uronic Acids, and Aldonic Acids by High Performance Anion- Exchange Chromatography Coupled with Pulsed Amperometric Detection in Corn Stover Prehydrolysates
A method for simultaneous separation and quantitative determination of arabinose, galactose, glucose, xylose, xylonic acid, gluconic acid, galacturonic acid, and glucuronic acid was developed by using high performance anion-exchange chromatography coupled with pulsed amperometric detection (HPAEC-PAD). The separation was performed on a CarboPac TM PA-10 column (250 mm × 2 mm) with a various gra...
متن کاملDetermination of saccharides in atmospheric aerosol using anion-exchange high-performance liquid chromatography and pulsed-amperometric detection.
An improved method is described for the quantification of primary sugars, sugar alcohols and anhydrosugars in atmospheric aerosols, making use of separation by high-performance anion-exchange chromatography (HPAEC) with pulsed amperometric detection (PAD). Quartz fibre filters from high-volume samplers were extracted with water and the extract injected directly. Repeatability is typically 4% RS...
متن کاملAnalysis of Carbohydrates by High-Performance Anion-Exchange Chromatography with Pulsed Amperometric Detection (HPAE-PAD)
Anion-Exchange Chromatography I. Mechanism of Separation Although anion-exchange chromatography has been used extensively to analyze acidic carbohydrates and glycopeptides, it has not been commonly used for analysis of neutral sugars. However, examination of the pKa values of the neutral monosaccharides listed in Table 1 shows that carbohydrates are in fact weak acids. At high pH, they are at l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of chromatography. A
دوره 997 1-2 شماره
صفحات -
تاریخ انتشار 2003