Focal Spots of Size l 23 Open Up Far-Field Florescence Microscopy at 33 nm Axial Resolution
نویسندگان
چکیده
We report spots of excited molecules of 33 nm width created with focused light of l 760 nm wavelength and conventional optics along the optic axis. This is accomplished by exciting the molecules with a femtosecond pulse and subsequent depletion of their excited state with red-shifted, picosecondpulsed, counterpropagating, coherent light fields. The l 23 ratio constitutes what is to our knowledge the sharpest spatial definition attained with freely propagating electromagnetic radiation. The sub-diffraction spots enable for the first time far-field fluorescence microscopy with resolution at the tens of nanometer scale, as demonstrated in images of membranes of bacillus megaterium.
منابع مشابه
Investigation of the Spatial Resolution and Field of View with Change of Magnification in VRX CT
Introduction: Variable resolution x-ray (VRX) CT is a new type of CT that can image objects at various spatial resolutions. In a VRX CT scanner, the spatial resolution increases at the cost of reduction in the field of view (FOV). An important factor that limits the spatial resolution of the VRX CT is the effect of focal spot size. Also, the optimum magnification is different at each incident a...
متن کاملFundamental improvement of resolution with a 4Pi-confocal fluorescence microscope using two-photon excitation
A new type of confocal fluorescence microscope with an unprecedented resolution is proposed. Calculations demonstrate that an axial resolution on the order of 100 nm can be achieved in a confocal microscope with enlarged aperture when two-photon excitation is applied. This axial resolution is up to four times higher than that ofa confocal fluorescence microscope. The proposed microscope yields ...
متن کاملPlasmonic hot spots: nanogap enhancement vs. focusing effects from surrounding nanoparticles.
Thin Au films (~5 nm) are known to form island-like structures with small gaps between the islands, which produce intense electric field "hot spots" under visible illumination. In this work, we perform finite difference time domain (FDTD) simulations based on experimentally observed high resolution transmission electron microscope (HRTEM) images of these films in order to study the nature of th...
متن کاملBreaking the diffraction barrier in fluorescence microscopy by optical shelving.
We report the breaking of the diffraction resolution barrier in far-field fluorescence microscopy by transiently shelving the fluorophore in a metastable dark state. Using a relatively modest light intensity of several kW/cm(2) in a focal distribution featuring a local zero, we confine the fluorescence emission to a spot whose diameter is a fraction of the wavelength of light. Nanoscale far-fie...
متن کاملThe effect of focal spot size on the spatial resolution of variable resolution X-ray CT scanner
Background: A variable resolution X-ray (VRX) CT scanner provides a great increase in the spatial resolution. In VRX CT scanners, the spatial resolution of the system and its field of view (FOV) can be changed according to the object size. One of the main factors that limit the spatial resolution of VRX CT scanner is the effect of the X-ray focal spot. Materials and Methods: A theoreti...
متن کامل