Reproducibility and automatic measurement of QT dispersion.

نویسندگان

  • J M Glancy
  • P J Weston
  • H K Bhullar
  • C J Garratt
  • K L Woods
  • D P de Bono
چکیده

This study investigated interobserver (two observers) and intrasubject (two measurements) reproducibility of QT dispersion from abnormal electrocardiograms in patients with previous myocardial infarction, and compared a user-interactive with an automatic measurement system. Standard 12-lead electrocardiograms, recorded at 25 mm.s-1, were randomly chosen from 70 patients following myocardial infarction. These were scanned into a personal computer, and specially designed software skeletonized and joined each image. The images were then available for user-interactive (mouse and computer screen), or automatic measurements using a specially designed algorithm. For all methods reproducibility of the RR interval was excellent (mean absolute errors 3-4 ms, relative errors 0.3-0.5%). Reproducibility of the mean QT interval was good; intrasubject error was 6 ms (relative error 1.4%), interobserver error was 7 ms (1.8%), and observers' vs automatic measurement errors were 10 and 11 ms (2.5, 2.8%). However QTc dispersion measurements had large errors for all methods; intrasubject error was 12 ms (17.3%), interobserver error was 15 ms (22.1%), and observers' vs automatic measurement were errors 30 and 28 ms (35.4, 31.9%). QT dispersion measurements rely on the most difficult to measure QT intervals, resulting in a problem of reproducibility. Any automatic system must not only recognize common T wave morphologies, but also these more difficult T waves, if it is to be useful for measuring QT dispersion. The poor reproducibility of QT dispersion limits its role as a useful clinical tool, particularly as a predictor of events.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of coronary artery bypass on QT dispersion

Introduction: QT dispersion (QT Max – QT min) reflects inhomogeneous ventricular depolarization that may provide a substrate for serious arrythmias and is associated with adverse clinical outcomes in patients with coronary artery disease. Some studies have shown reduction in QT dispersion after successful angioplasty due to coronary reperfusion, but effect of coronary artery bypass grafting o...

متن کامل

Measurement, interpretation and clinical potential of QT dispersion.

QT dispersion was originally proposed to measure spatial dispersion of ventricular recovery times. Later, it was shown that QT dispersion does not directly reflect the dispersion of recovery times and that it results mainly from variations in the T loop morphology and the error of QT measurement. The reliability of both automatic and manual measurement of QT dispersion is low and significantly ...

متن کامل

Measuring QT dispersion: man versus machine.

OBJECTIVE To compare manual and computer automated techniques for measuring QT dispersion. DESIGN Assessment of the ability of manual and automatic measurements of QT dispersion to discriminate between a normal group and two cardiac groups. SUBJECTS 12 simultaneous electrocardiogram leads were recorded from 25 healthy volunteers, 25 subjects after myocardial infarction, and 25 with cardiac ...

متن کامل

QT dispersion: time for an obituary?

Perhaps the believers and disbelievers represent two different poles of scientific and research attitude. Some believe that the original concept of QT dispersion is correct merely because the technology can be applied to existing ECGs, and that the results more or less frequently (irrespective of the reproducibility) statistically distinguish between clinically defined groups. Others point to t...

متن کامل

QT-Dispersion as a potential marker in prognosis of acute myocardial infarction

Introduction: QT dispersion in a 12 lead ECG represents the heterogeneity of ventricular repolarization. The prolongation of QT-interval dispersion increases the risk of coronary heart disease, ventricular arrhythmia, and sudden cardiac death in patients with myocardial infarction. We aimed to investigate the prognostic value of QT-dispersion in patients with acute myocardial infarction. Meth...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal

دوره 17 7  شماره 

صفحات  -

تاریخ انتشار 1996